Open the front
panel upward
Power
button
High
Speed
Forced Operation
Auto restart
Operating Instruction
Operation procedures when the remote control can't be
used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Heat pump Model
Cooling Model
Room Temp.
≥
24°C
21°C
≤
Room Temp. < 24°C
Room Temp. < 21°C
Operating mode
Cooling
Cooling
Healthy Dehumidification
Heating
Indoor FAN Speed
High
High
High
High
Setting Temperature
22°C
22°C
23°C
24°C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed
for about 3 seconds.
If you want to stop the operation, re-press the button.
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value when the
fan speed is set to high, and the capacity will be lower at low or medium
fan speed.
High fan speed is recommended when you wish to cool the room quickly.