![LG LSFD2491 series Service Manual Download Page 19](http://html.mh-extra.com/html/lg/lsfd2491-series/lsfd2491-series_service-manual_1902241019.webp)
- 19 -
3-23
CAUTION : Sealed System Repair
Before making a sealed system repair : Start with the power cord unplugged from the outlet. Plug in the power cord and
between 6 and 12 seconds after it has been pugged in, unplug it from the power source. this will allow both sides of the 3
way valve to be opened to allow for proper evacuation.
3-24 Way Valve Service
Whole picture of refrigerator
R-Evaporator
F-Evaporator
The 3 way valve has plastic parts inside, so always wrap
it with a wet cloth before servicing when using a torch.
1) Always replace the 3 way valve if there is a leak at any
one of the 3 tubes coming from it.
2) Service in replacement of valve (valve failure) Perform
service in the same method as above.
Note : To service sealed system, follow the directions in 3-22 and 3-23 above.Then service is the same as a single
evaporator system.
3 way valve
To Freezer(Refrigerant outlet)
Dryer Side(Refrigerant Inlet)
To Fresh Food
(Refrigerant outlet)
R-Evaporator
F-Evaporator
3 Way Valve
R-Evaporator
F-Evaporator
Summary of Contents for LSFD2491 series
Page 4: ... 4 2 PARTS IDENTIFICATION Ice Bin Icemaker Ice Compartment Door ...
Page 7: ... 7 ...
Page 26: ... 26 5 CIRCUIT DIAGRAM ...
Page 27: ... 27 6 TROUBLESHOOTING ...
Page 28: ... 28 ...
Page 30: ... 30 7 3 Sub PCB ...
Page 109: ... 109 13 DESCRIPTION OF FUNCTION CIRCUIT OF MICOM ...
Page 110: ... 110 ...