10-17
Copyright ©
LG Electronics Inc. All rights reserved.
Only training and service purposes
CHECKING FLOW CHART BY FAILURE
Oven hot, F6?
Is the resistance of
thermistor normal?
Check:
Pin 5 and 6 of CN6 of Main PCB
Normal – approximately
1.09
K
ohm at 25℃
No Replace the
defective
Thermistor
1
Unplug the unit
Yes
Yes
Yes
Yes
Is the heater relay normal?
Measure the resistance of
Heater relay and Live.
Normal : infinite
Abnormal : shorted
No
Replace the
Relay PCB
2
Broil Heater
Relay
Conv. Heater
Relay
Tap 09 and Tap07 : Ry 5
Tap 09 and Tap08 : Ry 6
CN06
Pin 5 and 6
Summary of Contents for LSEL6335D