1) Sensor resistance characteristics table
• Resistance value allowance of sensor is ±5%.
• When measuring the resistance value of the sensor, allow the temperature of that sensor to stabilize for at least 3 minutes
before measuring. This delay is necessary because of the sense speed relationship.
• Use a digital tester to measure the resistance. An analog tester has to great a margin of error.
• Resistance of the cold storage sensor 1 and 2 shall be measured with a digital tester
• Resistance of the freezing sensor shall be measured with a digital tester after separating CON7 of the PWB ASSEMBLY
and the MAIN part.
Measuring Temperature (°C)
Freezing Sensor
Cold storage sensor 1&2
Frost removal sensor, Outside sensor
-20 °C
22.3 k
77 k
-15 °C
16.9 k
60 k
-15 °C
13.0 k
47.3 k
-5 °C
10.1 k
38.4 k
0 °C
7.8 k
30 kΩ
+5 °C
6.2 k
24.1 k
+10 °C
4.9 k
19.5 k
+15 °C
3.9 k
15.9 k
+20 °C
3.1 k
13 kΩ
+25 °C
2.5 k
11 k
+30 °C
2.0 k
8.9 k
+40 °C
1.4 k
6.2 k
+50 °C
0.8 k
4.3 k
- 32 -