25
ENGLISH
CONNECTING AC
(LSAB009-M13, N13, M14, N14)
You can connect the unit to a power disconnecting device using an AC cable.
G
L
N
L
G
N
•
Use the AC cable to connect to the power disconnecting device. (Please use a cable that is long enough to be
connected to the screen.)
•
Please use a ferrite core to block out the noise from the power supply.
•
Please use 7 or more cores each to GND, L, and N when connecting to a master cabinet power cable.
* Manufacturer: TNC CO.,LTD.
14
7
8
(Unit: mm)
Power Connection
•
Prepare the power cable of 9 A (16 AWG) or more.
•
Check power cable color connection.
•
Avoid water or dust.