3. Insert the connecting cable into the indoor unit.
■
Don't connect the cable to the indoor unit.
■
Make a small loop with the cable for easy connection
later.
4. Tape the drain hose and the connecting cable.
5. Indoor unit installation
■
Hang the indoor unit from the hooks at the top of the
installation plate.
■
Insert the spacer etc. between the indoor unit and the
installation plate and separate the bottom of the indoor
unit from the wall.
6. Connecting the pipings to the indoor unit and the
drain hose to drain pipe.
■
Align the center of the pipings and sufficiently tighten
the flare nut by hand.
■
Tighten the flare nut with a wrench.
■
When extending the drain hose at the indoor unit, install
the drain pipe.
7. Wrap the insulation material around the connecting
portion.
■
Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
■
Wrap the area which accommodates the rear piping
housing section with vinyl tape.
- 29 -
Vinyl tape
Adhesive
Drain hose
Indoor unit drain hose
(narrow)
Plastic bands
Insulation material
Vinyl tape
(narrow)
Connection
pipe
Connecting
cable
Indoor
unit piping
Pipe
Vinyl tape
(wide)
Wrap with vinyl tape
Installation plate
Spacer
Indoor unit
8cm(3.15")
Indoor unit tubing
Flare nut
Pipings
Torque
wrench
Indoor
unit tubing
Spanner (fixed)
Connection
pipe
Flare nut
Pipe Size[Torque]
GAS
LIQUID
9K
1/2"[5.5kg.m]
1/4"[1.8kg.m]
12K
1/2"[5.5kg.m]
1/4"[1.8kg.m]
18K
5/8"[6.6kg.m]
1/4"[1.8kg.m]
24K
5/8"[6.6kg.m]
3/8"[4.2kg.m]
Capacity