16
Safety Precautions
Operating Instructions
Care and Maintenance
Troubleshooting Tips
Care and Maintenance
Operating Instructions
Safety Precautions
Care and maintenance of the air conditioner
CAUTION: Before performing any maintenance, turn off the main power to the system.
Indoor Unit
Grille, Case, and Remote Control
❏
Turn the system off before cleaning. To
clean, wipe with a soft, dry cloth. Do not
use bleach or abrasives.
NOTE:
Supply power must be disconnected before
cleaning the indoor unit.
AIR FILTERS
The air filters behind the front grille should be
checked and cleaned once in every 2 weeks or
more often if neccessary.
PLASMA FILTER, DEODORIZER
FILTER(OPTIONAL)
The PLASMA filter behind the air filters should be
checked and cleaned once in every 3 months or
more often if necessary.
❏
Never use any of the followings:
• Water hotter than 40°C
Could cause deformation and/or
discoloration.
• Volatile substances
Could damage the surfaces of the air
conditioner.
Lift the front access panel and pull the filter tab
slightly forward to remove the filter.
Clean the filter with a vacuum cleaner or
warm, soapy water.
• If dirt is conspicuous, wash with a
solution of detergent in lukewarm water.
• If hot water (40°C or more) is used, it
may be deformed.
After washing with water, dry well in the
shade.
Re-install the air filter.
Vertical louver Horizontal louver
Air filters
(behind front panel)
Air outlet vent
Air inlet vent
Gasoline
Powder
1
2
3
4
1
1
2
2
3
3
4
5
DEODORIZER Filter
PLASMA Filter
After removing the air filters, pull slightly
forward to remove the PLASMA filter.
Dip the PLASMA filter into the water mixed
with neutral detergent, for 20~30 minutes.
Dry the PLASMA filter in the shade for a day
(Especially, the humidity must be removed
perfectly on this parts).
Note the cuts of electric discharge lines.
Re-install the PLASMA filter to the original
position.
After removing the air filters, pull slightly
forward to remove the DEODORIZER filter.
Dry in the sunlight for two hours.
Re-install the DEODORIZER filter to the
original position.
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it may
cause an electric shock.
Summary of Contents for LS-J07 Series
Page 20: ...20 MEMO ...