2) Connection of Pipings
1. Remove the installation plate.
• Pull the two ‘
∆
’ marked portion of bottom of the
chassis and pull the installation plate out of
chassis.
2. Route the drain hose and the indoor tubing.
3. Connect the pipings and the indoor tubing, and
drain hose and drain pipe.
• Do not connect the cable to the indoor unit.
• Wrap the insulation material around the connect-
ing portion.
• Glue up the connection portion of drain hose and
drain pipe.
4. Insert the pipings, the connecting cables and
the drain pipe throught the piping hole on the
wall.
—15—
Installation plate
Pull
Pull
Indoor unit tubing
Flare nut
Spanner
Torque wrench
Plastic bands
Drain hose
Adhesive
Drain pipe
Insulation material
Pipings
Connecting cable
Connecting piping
Drain pipe
Indoor
Outdoor
;
;
For right rear piping
Pipe Size
Torque
Liquid Side (1/4")
1.8kg·m
Gas Side (3/8")
4.2kg·m