TROUBLE DIAGNOSIS
- 65 -
PROBLEM
CAUSE/CHECK POINTS
REMARKS
3. Refrigeration
is weak.
Plate
heater
Cord
heater
1) Refrigerant Partly leaked.
2) Poor defrosting capacity.
Drain path (pipe) clogged.
Defrost heater does not
generate heat.
Weld joint leak.
Parts leak.
Inject adiabatics into drain
hose.
Foreign materials
penetration.
Cap drain is not disconnected.
Inject through the
hole.
Seal with drain.
Adiabatics lump input.
Damage by a screw or
clamp.
Other foreign materials input.
Parts
disconnected.
Wire is cut.
- Heating wire.
- Contact point
between heating
and electric wire.
Dent by fin evaporator.
Poor terminal contacts.
Wire is cut.
- Lead wire.
- Heating wire.
- Contact point
between heating and
electric wire.
Heating wire is corroded
- Water penetration.
Bad terminal connection.
■
Check visually.
■
Check terminal
Conduction: OK.
No conduction: NG.
If wire is not cut, refer to
resistance.
P=Power
V=Voltage
R=Resistance
V
2
P= —
R
V
2
R= —
P
Summary of Contents for LRSC26910SW
Page 48: ...2 2 Parts list LRSC269 EXPLANATION FOR MICOM CIRCUIT 48 ...
Page 49: ...EXPLANATION FOR MICOM CIRCUIT 49 ...
Page 50: ...2 3 LRSC26944 LRSC26980TT DISPLAY ASSEMBLY part diagram EXPLANATION FOR MICOM CIRCUIT 50 ...
Page 51: ...DISPLAY circuit diagram EXPLANATION FOR MICOM CIRCUIT 51 ...
Page 53: ...DISPLAY circuit diagram EXPLANATION FOR MICOM CIRCUIT 53 PWB ASSEMBLY DISPLAY ...
Page 60: ...CIRCUIT 60 LRSC26944 LRSC26980TT ...
Page 102: ...TROUBLE DIAGNOSIS 102 ...
Page 111: ...6 BLOCK DIAGRAM TV RADIO 111 ...