5-13
2. Fuse does not
blow.
No continuity.
Continuity.
No continuity.
Defective power
supply cord.
Replace power
supply cord.
Defective
thermostat.
Replace
thermostat.
Check continuity
of thermostat.
Check continuity
of power supply
cord.
NOTE : All these switches must be replaced at the same time. Refer to page 5-7, 5-8
CONDITION
CHECK
RESULT
CAUSE
REMEDY
(TROUBLE 2) Oven does not operate at all, Display window does not display any figures,
and no input is accepted.
1. Fuse blows.
Continuity.
No continuity.
Malfunction of the
monitor switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of monitor
switch (with
door closed).
Continuity.
No continuity.
Shorted contact at
the primary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of primary
switch (with
door opened)
Continuity.
No continuity.
Malfunction of
secondary switch.
Replace fuse,
primary, monitor,
secondary
switches, and
RELAY(RY2) of
P.C.B Assembly.
Check continuity
of secondary
switch (with
door opened).
Normal.
Replace fuse
Fuse blows again
Defective high
voltage capacitor.
Replace high
voltage capacitor.
Disconnect one
side of the wire
lead connected
from transformer
to the high
voltage
capacitor and
operate the unit.
Defective high volt-
age transformer.
Replace high volt-
age transformer.
Summary of Contents for LRM1250W
Page 10: ...SCHEMATIC DIAGRAM 4 4 ...
Page 28: ...6 2 DOOR PARTS 13552A 13213A 13581A 14970A 14026A 13536A 15006A 14890A 13720D 143501 EV ...
Page 29: ...6 3 CONTROLLER PARTS 24781M 23506A 23572A 24510L 24970A 250201 268711 WTP018 EV ...
Page 30: ...6 4 OVEN CAVITY PARTS 33390G WTT010 WSZ185 33112U 35889A 36549S WTP013 33052A 948502 EV ...
Page 31: ...6 5 LATCH BOARD PARTS WSZ085 466001 466003 466001 43500A EV ...
Page 33: ...6 7 BASE PLATE PARTS 56170D WSZ002 WTT021 63302A 65006B 63303A EV ...
Page 34: ......