4-7
1. Refer to page 3-6 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from CR elements
4. Touch the ohmmeter test leads to the between
element terminal.
The meter should indicate 571
Ω
± 10%
Center Rear(CR)
Element
: Warming Zone
(Plane Heater)
Components
Test procedures
Results
Normal: Approximately 571
Ω
,
If not replace