-4-2-
COMPONENTS
TEST PROCEDURE
RESULTS
Oven Sensor
1. Refer to page 3-13 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1000)
Normal: Approximately
1.09 kΩ ± 10%
If not replace
Conv. heater
1. Remove wire leads
2. Measure resistance after cooling down
Normal : Approximately 27Ω
Abnomal : Infinite(opened)
Door switch
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x 1)
Door open
Door closed
Continuity
Infinite
NOTE: Ω Value was tested at room temperature
(77F/25˚C)
NOTE: Ω Value was tested at room temperature
(77F/25˚C)
Be careful the element is sensitive to
temperature.
Summary of Contents for LRE3061BD
Page 43: ... 5 2 COMPOSITION OF CONTROL Wiring Diagram ...
Page 46: ... 5 5 COMPOSITION OF CONTROL Oven Relay PCB CN103 CN102 CN17 CN16 CN101 CN100 ...
Page 47: ... 5 6 COMPOSITION OF CONTROL Cook top display PCB Key Pad ...
Page 76: ...CONTROLLER PARTS EV 2381 2031 2050 2006 260B 2048 2037 2042 2036 3006 2034 2041 2044 ...
Page 77: ...COOKTOP PARTS EV 3057 3014 3056 3302 3301 3303 3303 3401 3022 3204 3207 3401 3204 3204 3204 ...
Page 80: ......