7-1 FUNCTION
7-1-1 Function
1. When the appliance is plugged in, it is set to "4" for Refrigerator and "4" for freezer.
You can adjust the Refrigerator and the Freezer control temperature by pressing the ADJUST button.
2. When the power is initially applied or restored after a power failure, it is automatically set to "4" & "4".
7-1-2 Control of freezer fan motor
1. Freezer fan motor has high and standard RPMs.
2. High RPM is used when electricity is first on, for express freezing, and when refrigerator is overloaded.
But standard RPM is used for general purposes.
3. To improve cooling speed and load corresponding speed, the RPM of freezer fan motor shall change from normal speed
to hign speed.
4. High speed (2500RPM) : Initial power on or load corresponding operation, express freezing Normal speed (2200RPM) :
General working conditions.
5. Fan motor stops when refrigerator of freezer door opens.
7-1-3 EXPRESS FREEZING
1. The purpose of this function is to intensify the cooling speed of freezer and to increase the amount of ice.
2. Whenever selection switch is pressed, selection/release, the LED will turn ON or OFF.
3. If there is a power cut and the refrigerator is power on again, EXPRESS FREEZING function will be canceled.
4.To activate these function you need to press the Express Freezing key and the LED will turn ON. This function will remain
activated for 24 hrs. The first three hours the compressor and Freezer Fan will be ON. The next 21hours the freezer will
be controlled at the lowest temperature. After 24 hours or if the Express Freezing key is pressed again, the freezer will
return to its previous temperature.
5. For the first three hours notice the following cases:
(1) Compressor and freezer fan(HIGH RPM) continuously operate for three hours.
(2) If defrost starts during EXPRESS FREEZING, EXPRESS FREZZING operates for the rest of time after defrost is
completed, when EXPRESS FREZZING operation time is less than 90 minutes.
If EXPRESS FREZZING operates for more than 90minutes, the EXPRESS FREZZING will operate for two hours after
defrost is completed.
(3) If EXPRESS FREZZING is pressed during defrost, EXPRESS FREZZING LED is on but this function will start seven
minutes after defrost is completed and it shall operate for three hours.
(4) If EXPRESS FREZZING is selected within seven minutes after compressor has stopped, the compressor (compressor
delays seven minutes) shall start after the balance of the delay time.
(5) The fan motor in the freezer compartment rotates at high speed during EXPRESS FREZZING.
6. For the rest of 21 hours, the freezer will be controlled at the lowest temperature.
7-1-4. REFRIGERATOR LAMP AUTO OFF
1. To protect the risk of lamp heat, when Refrigerator door opens for 7 min., refrigerator lamp is auto off.
7. DESCRIPTION OF FUNCTION & CIRCUIT OF MICOM
- 16 -
BETTER / GOOD MODEL
ADJUST
WARMER
REFRIGERATOR TEMP
FREEZER TEMP
4 IS RECOMMENDED
COLDER
EXPRESS
FREEZING
ADJUST
WARMER
4 IS RECOMMENDED
COLDER
Summary of Contents for LRBN2051 Series
Page 9: ...BETTER GOOD 5 CIRCUIT DIAGRAM 9 3854JK1004D ...
Page 31: ...7 5 MAIN PWB ASSEMBLY AND PARTS LIST 7 5 1 Main PWB Assembly 31 ...
Page 32: ...7 5 2 Replacement Parts List 32 ...
Page 33: ...7 5 3 PWB Assembly Display And Parts List 33 ...
Page 34: ...7 6 PWB DIAGRAM 7 6 1 PWB Main Assembly 34 ...
Page 35: ... 35 ...
Page 36: ......