Freezer room lamp doesn’t work
1
Check the Freezer door switch.
Does it feel sticky?
Yes
No
7
Explain to customer
Change the
Door S/W
4
Check the LED Lamp voltage
Is voltage 12V? (While door open)
No
Yes
Change the
LED Lamp
Voltage [V]
CON6
19
th
pin ~ 17
th
pin
12V
2
Check the door S/W resistance.
Is it correct compared with table?
No
Yes
Change the
Door S/W
Door S/W
3
Check the PCB Voltage.
Is CON6 19
th
pin ~ 17
th
pin
voltage 12V?
No
Yes
Change the
PCB
CON6
S/W Resistance [
Ω]
Door
Open
0
Close
Infinity
Summary of Contents for LMXS27676D
Page 1: ...MODEL LMXS27676D COLOR Black STS SB ...
Page 4: ... 4 ...
Page 5: ... 5 ...
Page 20: ...5 CIRCUIT DIAGRAM 5 1 20 ...
Page 23: ... P N EBR60070711 33 7 PCB Picture 7 3 Sub PCB ...
Page 73: ... 73 10 COMPONENT TESTING INFORMATION 10 1 P71 list ...
Page 106: ...600A 630F 630B 630A 630H 630G 630C 630Q 630E 630D 611A 612A 630J 606A 630J 607A ...
Page 107: ......