7-13
A. PRIMARY INTERLOCK SWITCH TEST
When the door is opened slowly, an audible click
should be heard at the same time or successively
at intervals and the latches should activate the
switches with an audible click.
If the latches do not activate the switches when the
door is closed, the switches should be adjusted in
accordance with the adjustment procedure.
Disconnect the wire lead from the primary switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminal of the
switch. The meter should indicate an open circuit
in the door open condition.
When the door is closed, the meter should indicate
a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch with the same type of switch.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary
switch.
Connect the ohmmeter leads to the common
(COM) and normally open (NO) terminals of the
switch. The meter should indicate an open circuit
in the door open condition. When the door is
closed, the meter should indicate a closed circuit.
When the secondary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the ohmmeter leads to the common
(COM) and normally closed (NC) terminals of the
switch. The meter should indicate a closed circuit
in the door open condition. When the door is
closed, the meter should indicate an open circuit.
When the monitor switch operation is abnormal,
replace with the same type of switch.
NOTE: After repairing the door or the interlock
system, it is necessary to do this continuity
test before operating the oven.
WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION, REPLACE ONLY WITH IDENTICAL REPLACEMENT PARTS.
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR PRIMARY SWITCH
TYPE NO. SZM-V16-FA-62 OR VP-532A-OF OR V-5220Q FOR MONITOR SWITCH
TYPE NO. SZM-V16-FA-63 OR VP-533A-OF OR V-5230Q FOR SECONDARY SWITCH
COMPONENTS
TEST PROCEDURE
RESULTS
SWITCHES
Check for continuity of the
Door
Door
(Wire leads removed)
switch with an Ohm-meter
open
closed
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE : After checking for the continuity of switches, make sure that they are
connected correctly.
NO
COM
NC
COM
NO
COM
INTERLOCK CONTINUITY TEST
Summary of Contents for LMVM1945SB
Page 9: ...5 1 SCHEMATIC DIAGRAM OVERALL CIRCUIT DIAGRAM ...
Page 10: ...5 2 MATRIX CIRCUIT FOR TOUCH KEY BOARD ...
Page 37: ...8 2 CONTROLLER PARTS I 23506A 268711 ...
Page 38: ...8 3 CONTROLLER PARTS II 268712 WTT028 250201 23572A 24810P 24781M ...
Page 40: ...8 5 LATCH BOARD PARTS 43500A WSZ085 43501A 466001 466003 466001 44510A ...
Page 44: ...8 17 SCHEMATIC DIAGRAM OF P C B ...
Page 45: ...8 18 PRINTED CIRCUIT BOARD ...