-33-
COMPONENTS
TEST RESULTS
Normal:
Approximately
Turbo speed: 20 to 30 ohms
High speed: 40 to 50 ohms
Low speed: 45 to 55 ohms
Normal: Approximately
2.0 to 3.0 Kohms
Abnormal:
Infinite or several.
Normal:
Approximately
BK-RD: 6.0 Kohms
RD-WH: 3.0 Kohms
BK-WH: 3.0 Kohms
Abnormal:
Infinite or approx. 0 ohm
1.Remove lead wires.
2.Measure resistance.
(ohm meter scale: Rx1)
Turbo speed: blue & black wire
High speed: blue & white wire
Low speed: blue & gray wire
1. Remove wire leads.
2. Measure resistance.
(ohm meter scale: Rx1000)
VENTILATION MOTOR
TURNTABLE MOTOR
1. Disconnect sensor connector from micom
computer board.
2. Measure resistance terminal to terminal (ohm
meter scale: R X 1000)
ABSOLUTE HUMIDITY
SENSOR
1.Remove lead wires.
2.Measure resistance.
(ohm meter scale: Rx1000)
Normal:
Approximately 120 to 135 ohms
Abnormal: Infinite
STIRRER MOTOR
Summary of Contents for LMV1813SB
Page 9: ...5 WIRING DIAGRAM KEY MATRIX 9 5 1 Wiring Diagram ...
Page 14: ... 14 6 4 Troubleshooting No Display or Dead ...
Page 17: ... 17 Keypad Failure MICOM Start key or EZ ON key works if the door is closed ...
Page 19: ... 19 No Heat No Cook ...
Page 46: ... 49 LATCH BOARD PARTS W102 4000 4002 4003 4001 4004 4002 EV ...