– 5 –
Parts, Tools, Materials
THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN:
NOTE: Depending on your ventilation requirements, you may not use all of these parts.
Damper/duct connector
(for roof venting or wall venting installation)
Not Actual Size (2 pieces must be assembled as
shown) Not used if venting into kitchen.
One power cord clamp
and
One dark-colored mounting screw
(to hold the power cord)
Actual Size
Four 1/4" x 2" lag screws
- Actual Size
(for wall stud holes)
Three
1/4" x 3" toggle bolts -
Actual Size
(for drywall holes)
Two 1/4" x 3" bolts -
Actual Size
(for securing to the upper cabinet
Three
1/4" x 3" bolts -
Actual Size
(for securing to the upper cabinet)
Two tapping screws
- Actual Size
(for attaching the damper duct connector)
One upper cabinet template-
Not Actual Size
One rear wall template-
Not
Actual Size
(
1
piece mounting plate only)
One power cord clamp bushing
- Actual Size (for the cord hole in a metal upper cabinet)
NOTE: You need to install at least
one
lag screws into a 2" x 4" stud and
three
anchor bolts into the wall.
and the mounting area must meet the 150 lbs. weight requirement.
D
A
B
C
4922W5A060E
Printed in China
NOTE: IT IS VERY IMPORTANT TO
READ AND FOLLOW THE DIRECTIONS
IN THE INSTALLATION INSTRUCTIONS
BEFORE PROCEEDING WITH THIS
REAR WALL TEMPLATE.
1.
Place the template flat against the rear
wall, aligning the circles
A
and
B
with the
corresponding holes previously drilled in the
rear wall for holes A and B of the wall plate.
2.
With the template aligned to the holes, tape the
template to the rear wall.
3.
Use a saber or keyhole saw to cut out the shaded
area F. through the rear wall.
4.
Remove the template from the rear wall.
5.
RETURN TO AND PROCEED WITH THE
INSTALLATION INSTRUCTIONS.
1/4
″
12
4
F. CUT OUT FOR WALL
VENTED ONLY
CUT HOLE THROUGH REAR WALL FOR EXHAUST ADAPTOR
REAR WALL TEMPLATE
Locate and mark holes to align with holes in the
mounting plate.
IMPORTANT:
LOCATE AT LEAST ONE STUD ON EITHER SIDE OF
THE CENTERLINE.
MARK THE LOCATION FOR 2 ADDITIONAL, EVENLY
SPACED TOGGLE BOLTS IN THE MOUNTING PLATE
AREA.
C L
Locate and mark holes to align with holes in the
mounting plate.
IMPORTANT:
LOCATE AT LEAST ONE STUD ON EITHER SIDE OF
THE CENTERLINE.
MARK THE LOCATION FOR 2 ADDITIONAL, EVENLY
SPACED TOGGLE BOLTS IN THE MOUNTING PLATE
AREA.
30
″
MINIMUM WIDTH REQUIRED
CAUTION – IF EXHAUST ADAPTOR IS POSITIONED OUTSIDE
RECOMMENDED DIMENSION, GREASE-LADEN AIR WILL
DISCHARGE INTO HOUSE STRUCTURE.
Summary of Contents for LMV1683ST
Page 18: ...Printed in China ...