13
INSTALLATION
ENGLISH
InSTALLATIOn
Product Specifications
The appearance and specifications listed in this manual may vary due to constant product improvements.
Oven range Models
LSD4913
Description
Dual Fuel Range
Electrical requirements
4.2 kW 120/240 VAC or 3.2 kW 120/208 VAC
Exterior Dimensions
29
7
/
8
" (W) x 37
7
/
8
" (H) x 26
1
/
2
" (D) (D with door closed)
75.7 cm (W) x 96 cm (H) x 67.3 cm (D) (D with door closed)
Height to cooking surface
36" (91.4 cm)
net weight
181 lb (82.0 kg)
Total capacity
Total cap.: 6.3 cu. ft.
Before Installing the range
Make sure your range is properly installed and grounded by a qualified installer, according to the installation
instructions. Any adjustment and service should be performed only by qualified gas range installers or service
technicians.
In the Commonwealth of Massachusetts
•
This product must be installed by a licensed plumber or gas fitter.
•
When using ball type gas shut-off valves, they must be the T-handle type.
•
When using a flexible gas connector, it must not exceed 3 feet in length.
Preparing for Installation
Tools needed
Phillips screwdriver
Open-end or adjustable
wrench
Pencil and ruler
Level
Flat-blade screwdriver
Pipe wrench (2)
(one for support)
Materials You May need
•
Gas line shut-off valve
•
Pipe joint sealant that resists action of natural and LP gases
•
Flexible metal appliance connector (
3
/
4
" or
1
/
2
" NPT x
1
/
2
" I.D.)
Never use an old connector when installing a new range.
•
Flare union adapter for connection to gas supply line (
3
/
4
" or
1
/
2
" NPT x
1
/
2
" I.D.)
•
Flare union adapter for connection to pressure regulator on range (
1
/
2
" NPT x
1
/
2
" I.D.)
•
Liquid leak detector or soapy water
•
Lag bolt or
1
/
2
" O.D. sleeve anchor (for concrete floors only)