background image

CAUTION

CAUTION

CAUTION

CAUTION

4

• Contact the authorized Service technician for repair or maintenance of this unit.

• Contact the installer for installation of this unit.

• The air conditioner is not intended for use by young children or infirm persons without

supervision.

• Young children should be supervised to ensure that they do not play with the air conditioner.

When the air filter is to be
removed, do not touch the
metal parts of the indoor unit.

• It may cause an injury.

• Should be disconnected from

supply

Do not clean the air
conditioner with water.

• Water may enter the unit and

degrade the insulation. It may
cause an electric shock.

Ventilate well when used
together with a stove, etc.

• An oxygen shortage may

occur.

When the unit is to be
cleaned, switch off, and
turn off the circuit breaker.

• Since the fan rotates at high

speed during operation, it may
cause an injury.

Do not put a pet or house
plant where it will be
exposed to direct air flow.

• This could injure the pet or

plant.

Do not leave on installation
stand which is damaged.

• The unit may drop or fall down

and cause an injury.

Do not apply an insecticide
or flammable spray.

• It may cause a fire or

deformation of the cabinet.

Do not put a stove, etc.
where is exposed to direct
air flow.

• It may affect combustion.

Do not step on the
indoor/outdoor unit and
do not put anything on it.

• It may cause an injury through

dropping or falling down.

Do not insert hands
through vanes when the air
conditioner is operationg

• It will cause an injury by the

rotating blower.

When the unit is not going
to be used for a long time,
turn off the circuit breaker.

• If not, dirt may collect and

cause a fire.

Do not step onto an unstable
bench when cleaning and/or
maintaining the unit.

• It may cause an injury, etc. by

falling down.

Do not use for special purposes.

• Do not use this air conditioner to preserve

precision devices, food, animal, plants, and
art objects.
It may cause deterioration of quality, etc.

Do not operate for a long time in high
humidity, e.g. leaving a door or window
open.

• In the cooling mode, if it is operated in a

room with high humidity (80%RH or more) for
a long time, water condensed in the air
conditioner may drop and may wet and spoil
furniture, etc.

Summary of Contents for LM-2063H3L

Page 1: ... close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation LG is not responsible for any damages caused by misuse of the product LG Multi Type Air Conditioner OWNER S MANUAL LG Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 3 Norm ENGLISH ITALIANO E...

Page 2: ... may not need to call for service at all Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air conditioner When the power cord is to be replaced r...

Page 3: ... in damp environment Do not direct airflow at room occupants only It will cause electric shock or fire due to heat generation It may cause electric shock This could damage your health Always perform grounding work Do not allow water to run into electric parts Always install air leakage breaker and a dedicated switching board No grounding may cause electric shock See Installation Manual It may caus...

Page 4: ...installation stand which is damaged The unit may drop or fall down and cause an injury Do not apply an insecticide or flammable spray It may cause a fire or deformation of the cabinet Do not put a stove etc where is exposed to direct air flow It may affect combustion Do not step on the indoor outdoor unit and do not put anything on it It may cause an injury through dropping or falling down Do not ...

Page 5: ...torage and Tips For Using the Remote Control The remote control may be stored mounted on a wall To operate the room air conditioner aim the remote control at the signal receptor Signal Receptor Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Operation Indication Lamps On Off Lights up during the system operation Sleep Mode Lights up during Sleep...

Page 6: ...tart or stop the speed cooling Speed cooling operates super high fan speed in cooling mode CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation TIME SETTING BUTTONS Used to adjust the time See page 13 TIMER SET CANCEL BUTTONS Used to set the timer when the desired time is ...

Page 7: ...ature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Cooling Operation Natural wind by the CHAOS logic For more fresh feeling than other fa...

Page 8: ... door on the remote control and press the Room Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will then be changed automatically DURING AUTO OPERATION You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired manually switch to another mode The ...

Page 9: ... button the A C starts to run the dehumidification function automatically setting the room temp and airflow volume to the best condition for dehumidification based on the sensed current room temp In this case however the setting temp is not displayed in the remote control and you are not able to control the room temp either During the healthy dehumidification function the airflow volume is automat...

Page 10: ...t the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments Heating Operation Heat pump model only Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted NATURAL WIND BY THE CHAOS LOGIC Fo...

Page 11: ...speed on cooling mode Jet Cool Operation NOTE During the JET COOL function at any moment the A C starts to blow the cool air at extremely high speed for 30 minutes setting the room temp automatically to 18 C It is especially used to cool the room temp in the shortest time in a hot summer In heat pump mode or neuro fuzzy mode however the JET COOL function is not available In order to return to the ...

Page 12: ...gain with door of the remote control closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA can be with cooling Heating or any other operations PLASMA Air Purifying Operation only If you press the only PLASMA button only PLASMA air purifying operates Then fan speed is low You can select...

Page 13: ... temperature will automatically rise by 1 C over the next 30 minutes and by 2 C in 1 hour for comfortable sleeping Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Start Stop button Press the Time Setting buttons until the desired time is set Press the Timer SET button Note Check the i...

Page 14: ...n Manually moving the vertical airflow direction louver by hand could damage the air conditioner When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system To adjust left right Horizontal Airflow direction Caution Ensure unit is turned off before adjusting the horizontal airflow direction control Carefully open vertical louver to allow access to the...

Page 15: ...estarting Operation is the function to operate procedures automatically to the previous operating conditions If you want to use this operation Open the front panel upward and move the slide switch to the Auto Restart position If you do not want to use this operation move the Slide Switch to the Remote Control position Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C ...

Page 16: ...t water 40 C or more is used it may be deformed After washing with water dry well in the shade Re install the air filter Vertical louver Horizontal louver Air filters behind front panel Air outlet vent Air inlet vent Gasoline Powder 1 2 3 4 1 2 3 4 5 1 2 3 After removing the air filters pull slightly forward to remove the PLASMA filter Dip the PLASMA filter into the water mixed with neutral deterg...

Page 17: ... panel and remove air filters Reinsert air filters and close front panel Remove air purifying filters Insert new air purifying filters The heat exchanger coils and panel vents of the outdoor unit should be checked regularly If clogged with dirt or soot the heat exchanger and panel vents may be professionally steam cleaned NOTE Dirty or clogged coils will reduce the operating efficiency of the syst...

Page 18: ...ing filters Check that the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air condit...

Page 19: ...curs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed For a noise that sounds like water flowing This is the sound of freon flowing i...

Page 20: ...20 Note ...

Page 21: ...P No 3828A20159B Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...

Reviews: