Summary of Contents for LGXXXQ1CK-A5

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXQ1C K A5 MFL69534401 Rev 01 www lgsolarusa com Installation manual PV Solar MODULE ...

Page 2: ...06 Diodes 06 Series Connection 06 Parallel Connection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 12 APPENDIX 13 ...

Page 3: ...t be treated with safety protection equipment Failure to comply may result in serious bodily injury or death Do not approach the damaged or broken module unless you are an authorized or qualified expert Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junc...

Page 4: ... product damage or failure Do not apply a shock to the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the...

Page 5: ...e installation site Do not work alone Please work as part of a team of two or more people Safety harness use is strongly recommended for installation Partial shadowing may substantially reduce panel and system output Care must be taken to avoid low tilt angles which may cause dirt to buildup on the glass against the frame edge Dirt build up on the surface of the panel may cause active solar cells ...

Page 6: ...ng as it is within the guidelines on the product specification sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables the connector of each module should be the same products EL...

Page 7: ... by the applicable codes LG Electronics recommends a size no smaller than 12AWG Earth Grounding All work must be conducted in conformance with all Federal State and local codes and standards Grounding works should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and lo...

Page 8: ...ion Select the appropriate orientation to maximize sunlight exposure Module should not be mounted or stored in a way that the front top glass faces downward in order to prevent water from entering the junction box which could cause a safety hazard Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behi...

Page 9: ...ounting by using frame bolts holes Secure the solar module to the structure by using the factory mounting holes Four M8 5 16inch stainless steel bolts four nuts recommended per solar module The module may be fastened to a support by using both the outer and inner bolt holes of the frame Each module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting hol...

Page 10: ...to be caused in whole or in part by the negligence and employees Disposal Please contact us if you have any queries related to the disposal or recycling of solar modules from LG Electronics 10 DISCLAIMER OF LIABILITY DISPOSAL Do not loosen the banding when the module is transported by truck ship and etc In case of loose banding the module will be shaken which may cause damage Do not stack on more ...

Page 11: ...05 8 1700 1016 40 18 5 LG320Q1K A5 320 3 42 5 34 7 9 31 20 1000 MC4 05 8 1700 1016 40 18 5 LG325Q1K A5 325 3 42 5 10 72 35 0 9 38 20 1000 MC4 05 8 1700 1016 40 18 5 LG330Q1K A5 330 3 42 5 10 73 35 2 9 45 20 1000 MC4 05 8 1700 1016 40 18 5 LG335Q1K A5 335 3 42 6 10 74 35 4 9 53 20 1000 MC4 05 8 1700 1016 40 18 5 LG340Q1K A5 340 3 42 6 10 75 35 7 9 60 20 1000 MC4 05 8 1700 1016 40 18 5 LG345Q1K A5 3...

Page 12: ...12 Dimensions of Modules 60Cell Module Note Holder is for the convenient connection of junction box cable but that does not warranty if it is broken after installed Unit mm in ...

Page 13: ...B A 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop d n i w s a h c u s d n a t s l a n o i t i d d a n a h t i w d e l l a t s n i f I f o o r t a l F 2 A 200mm 5 9 in B 400mm 15 7 in Front 6000Pa 125psf Rear 5400Pa 113psf m m 0 2 1 A 4 7 in 4point Front 1800Pa 37 5psf Rear 1800Pa 37 5psf C 120mm 4 7in Front 3200Pa 67psf Rear 1800...

Page 14: ...kmount PV Quick Rack Panel Clamp SnapNrack SnapNrack Bonding Mid Clamp SnapLink for RL system Ecolibrium EcoX Clamp and Coupling assembly EcoFoot Clamp Pegasus Pegasus LightSpeed Corners Schletter Rapid Grounding Module Clamps Dynorax DynoBond Roof Tech Roof Tech Bonding Plate ILSCO ILSCO SGB 4 Solar Grounding Lug TYCO TYCO 2058729 2106831 SolarLock Grounding Assy Wiley Burndy WEEB LUG WEEB KMC in...

Page 15: ...ct lg solar lge com http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...