Danger

 

Avoid all electrical hazards when installing, wiring, 
operating and maintaining all panels.

 

Do not connect panels that have different electrical 

system.

 

Match the polarities of cables and terminals when 
making the connections; failure to do so may result in 
damage to the panel.

 

The rating of the over-current device shall not exceed 
the maximum series fuse rating marked on the name 
plate.

 

The panel contains factory installed bypass diodes 
located inside the  junction box.

 

When installing the system, it is recommended to 
install a lightning rod to protect the system.

 

The induced overvoltage by lightning can cause the 
system damage, you should design conductor loop 
connection as minimum as possible.

 

The junction box should not be opened. Opening the 
junction box will void the warranty.

 

Panels with a suspected electrical problem should be 
returned to LG Electronics for inspection and possible 
repair or replacement as per the warranty conditions 
provided by LG Electronics.

Electrical Connections

 

Shock hazard may occur near the solar modules 
electrical connections.

 

Modules may be connected in series and/or parallel 
to achieve the desired electrical output as long as it 

sheet.

 

Please use only the same type of modules in a 
combined source circuit. 

 

Do not disconnect the module under when it is 
operating. Shock hazard may occur near the solar 
modules connection means. 

 

When the module installing in series or in parallel (e.g. 
using for extension cables, etc.), the connector of each

original female or male connector of the same supplier)

module should be the same products. (mated with its

ELECTRICAL INSTALLATION

Diodes

 

All LG modules are equipped with factory installed 
bypass diodes. The factory-installed diodes provide 
proper circuit protection for the module from 
unexpected shadows. 

Diode specification and configuration

+

-

1

D1

D2

D3

2

3

4

I

F

 

(AV)

25A

V

F

 (max)

0.6V

V

RRM

50V

T

j

 

(max)

200°C

R

TH

2.0°C/W

Series Connection

 

The solar modules may be wired in series to produce 
the desired voltage output. 

 

The current of each module connected in series 
should be the same.

 

The maximum PV system voltage for that circuit shall 
be calculated as the sum of the rated open-circuit 
voltage of the series-connected PV modules corrected 
for the lowest expected ambient temperature. For the 
LG Mono crystalline modules, the rated open-circuit 
voltage shall be multiplied by the correction factor 
provided in NEC Table 690.7.  The maximum current 
of Photovoltaic Source Circuit Currents shall be the 
rated short-circuit current of the series-connected 
module multiplied by 125 percent in accordance with 
NEC article 690.8.

Summary of Contents for LG Q1C-V5 Series

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXQ1C V5 LGXXXQ1K V5 www lgsolarusa com Installation manual PV Solar MODULE MFL71300801 ...

Page 2: ... Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules Mechanical Installation methods Bolting Clamp Information Alternate Equipment Grounding Devices Unloading Flow Guid...

Page 3: ...t be treated with safety protection equipment Failure to comply may result in serious bodily injury or death Do not approach the damaged or broken module unless you are an authorized or qualified expert Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junc...

Page 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Page 5: ...ratures may substantially increase voltage and power Keep the solar module and system away from children at all times Keep the module packed in the carton until the time of installation site Do not work alone Please work as part of a team of two or more people Safety harness use is strongly recommended for installation Partial shadowing may substantially reduce panel and system output and may be t...

Page 6: ...y the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables etc the connector of each original female or male connector of the same supplier module should be the same products mated with its ELECTRICAL ...

Page 7: ...ned by the applicable codes LG Electronics recommends a size no smaller than 12AWG Earth Grounding All work must be conducted in conformance with all Federal State and local codes and standards Grounding works should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and...

Page 8: ...ics can not be This mounting method is by using frame bolt holes The mounting rails must run perpendicularly to the module long side operated in a location where they could come in direct contact with salt water or ammonia Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure Module should not be mounted or stored in a way that the front top glass fa...

Page 9: ...ombination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanical Installation Scene Refer to Appendix r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I compatibility by LGE If the installation is likely to be affec...

Page 10: ...employees Disposal Please contact us if you have any queries related to the disposal or recycling of solar modules from LG Electronics 10 DISCLAIMER OF LIABILITY DISPOSAL Do not loosen the banding when the module is transported by truck ship and etc In case of loose banding the module will be shaken which may cause damage Do not stack on more than one pallet Maximum height is two pallets Severe st...

Page 11: ...p at STC Max Series Fuse Rating Max No of module in series Max System Voltage Connector Length Width Height Weight W V A V A A V mm mm mm kg LGXXXQ1C V5 LGXXXQ1K V5 345 0 3 42 6 10 76 35 8 9 64 18 350 0 3 42 7 10 77 36 1 9 70 18 340 0 3 42 6 10 75 35 6 9 56 18 20 1000 MC4 JM608 1700 1016 40 17 5 20 1000 MC4 JM608 1700 1016 40 17 5 20 1000 MC4 JM608 1700 1016 40 17 5 20 1000 MC4 JM608 1700 1016 40 ...

Page 12: ...12 Dimensions of Modules 60Cell Module Unit mm in LGXXXQ1C K V5 ...

Page 13: ...0Pa 38psf B 200mm 7 9 in Front 2400Pa 50psf Rear 2400Pa 50psf Fig 5 Clamping Type Fig 6 Clamping Type A B B A C C B A A 200mm 7 9 in B 400mm 15 7 in Front 5400Pa 113psf Rear 4000Pa 84psf A 120mm 4 7 in 4point Front 1800Pa 38psf Rear 1800Pa 38psf C 120mm 4 7 in Front 5400Pa 113psf Rear 1800Pa 38psf A 120mm B 843 100mm 33 2 3 9 in 6point Front 5400Pa 113psf Rear 4000Pa 84psf Note All mechanical inst...

Page 14: ...nts Use corrosion resistant material clamps and hardware E G L y b y t i l i b i t a p m o c r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I The clamp should not be touched with the module s glass Use appropriate bolted connections as per clamp manufacturer s instructions Follow the clamp manufacturer s recommended applied torque to fasten the clamps Middle Clamp Edge Cla...

Page 15: ...k Rack Panel Clamp SnapNrack SnapNrack Bonding Mid Clamp SnapLink for RL system Ecolibrium EcoX Clamp and Coupling assembly EcoFoot Clamp Pegasus Pegasus LightSpeed Corners Schletter Rapid Grounding Module Clamps Dynorax DynoBond Roof Tech Roof Tech Bonding Plate ILSCO ILSCO SGB 4 Solar Grounding Lug TYCO TYCO 2058729 2106831 SolarLock Grounding Assy Wiley Burndy WEEB LUG WEEB KMC in combination w...

Page 16: ... Block Block Block Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging ...

Page 17: ...t lg solar lge com http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...

Reviews: