background image

04

Do not touch the glass surface or 

frame of the solar module after 

installation of the module. It may 

result in injury or death.

Heavy objects must be kept off of 

the solar module.

Do not stand on or step on the 

module. Do not drop the module. 

Failure to comply may result in 

product damage, product failure 

or bodily injury. 

Do not scratch the coating 

surface of the frame. 

Scratches may decrease the total 

solar output due to corrosion of 

the frame.

sunlight on the solar module 

Do not artificially concentrate

surface. Failure to comply may 

result in product damage or 

failure.

Do not apply a shock to the 

junction box of the module or 

pull the cable. Do not remove the 

labels attached to the module. 

Failure to comply may result in 

damage of the product.

If the installing modules on curved surface, (e. g. arch 

type), as shown in the below picture, do not forcefully 

modify the module in the installation when connecting 

it with the structure. Only install the module in the place 

where the structure for the panels  has been properly 

set up. An improper structure may cause deformation 

of the panels. Panels may also be damaged by 

unapproved installation methods such as the use of a 

crane.

Module

Installing structure
(bent type)

Module

Installing structure
(Stralght type)

Product

Deformation

Occurrence

of space

Partial shadow must be removed 

from solar module because it can 

cause severe problems of solar

module.

Summary of Contents for LG N1K-N6 Series

Page 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODEL www lg solar com Installation manual PV Solar MODULE LGXXXN1K N6 ...

Page 2: ...onnection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 11 REVISIONS TABLE 11 PRODUCT SPECIFICATIONS 12 Electrical Mechanical Properties 12 Dimensions of Modules 14 Mechanical Installation methods Bolting Clamp Information Unloading Flow Guide 15 17 18 APPE...

Page 3: ...ed modules must be treated with safety protection equipment Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junction box cable It may occur spark or electric shock Do not bending junction box s cable While under stress it may occur module damage Cable ben...

Page 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Page 5: ... and system output and may be the reason for the damage of solar module Dirt build up on the surface of the panel may cause active solar cells to be shaded and electrical performance to be impaired conditions of 1000W m2 irradiance and 25 C 77 F solar cell temperature Colder temperatures may substantially increase voltage and power Industry standard rated specifications are made at site Keep flamm...

Page 6: ... connections Modules may be connected in series and or parallel to achieve the desired electrical output as long as it sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using for extension cables etc...

Page 7: ...sher Grounding wire Spring washer Nut Flat washer Maximum series fuse rating is refer to Product Specifications page 11 Parallel connection for more current LG Electronics recommends a size no smaller than 4mm 2 General Wiring LG Electronics recommends that all wiring be double insulated with a minimum rating of 90 C 194 F The minimum size should be determined by the applicable codes All wiring sh...

Page 8: ...e that there is no shadowing affected by building chimney tree and neighboring module etc Mounting Rails No of Cell Do not use module to replace or partly replace roofs and walls of living places Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure The module generates maximum output power when it faces the sun directly The tilt angle of the modules...

Page 9: ...ch module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting holes is provided in Product Tighten the bolt securely by using the combination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanic...

Page 10: ...lectrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance either to the shop ...

Page 11: ... occur Packaged modules should be stored in a cool and dry place The module packaging is not water weatherproof If stored for a long time in an uncontrolled environment it can cause discoloration problems of solar module This installation manual Version 1 replaces all previous versions except electrical and mechanical characteristics For electrical and Mechanical characteristics of each model plea...

Page 12: ...TC Vmpp at STC Impp at STC Max Series Fuse Rating Max No of module in series Max System Voltage Connector Length Width Height Weight W V A V A A V mm mm mm kg 40 6 10 83 33 9 10 35 40 8 10 93 34 0 10 44 41 0 11 03 34 3 10 51 41 2 11 13 34 5 10 60 41 4 11 23 34 7 10 68 41 5 11 33 34 9 10 75 41 7 11 43 35 2 10 83 18 5 18 5 18 5 18 5 18 5 18 5 18 5 MC4 05 8 PV CO02 MC4 05 8 PV CO02 MC4 05 8 PV CO02 M...

Page 13: ...pp A Open Circuit Voltage Voc V Short Circuit Current Isc A 264 31 9 8 29 38 2 8 72 355 268 32 0 8 36 38 3 8 80 360 272 32 3 8 42 38 5 8 88 365 276 32 4 8 49 38 7 8 96 370 279 32 7 8 56 38 9 9 05 375 283 32 9 8 61 39 1 9 13 380 287 33 1 8 68 39 3 9 21 LGXXXN1K N6 NMOT Nominal Module Operating Temperature Irradiance 800W m ambient temperature 20 wind speed 1m s 2 PRODUCT SPECIFICATIONS ...

Page 14: ...14 Dimensions of Modules 60Cell Module Unit mm in LGXXXN1K N6 Frame Cross section Note Cable length with connector MC4 05 8 PV CO02 Long Frame Short Frame ...

Page 15: ... Pa Position mm 240 440 5400 4000 Load Front Rear Pa Position mm 234 or 334 5400 4000 Load Front Rear Pa Position mm 240 440 5400 4000 Load Front Rear Pa Position mm 0 300 5400 2400 Load Front Rear Pa Position mm 0 50 0 650 2400 2400 A B Fig 3 Clamping Type Note All mechanical installation methods and bolting method in this appendix were not tested by CSA or 3rd party It is evaluated by LG interna...

Page 16: ...ar Pa Position mm 0 50 0 650 2400 2400 A B Load Front Rear Pa Position mm 240 440 4000 4000 Fig 7 Clamping Type Fig 8 Clamping Type Fig 9 Clamping Type APPENDIX Mechanical Installation 60Cell Model 16 Note All mechanical installation methods and bolting method in this appendix were not tested by 3rd party It is evaluated by LG internal test 0 4 4 0 4 2 ...

Page 17: ...shers and eight flat washers are recommended per solar module Bolting Method Clamp system requirements Use corrosion resistant material clamps and hardware E G L y b y t i l i b i t a p m o c r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I The clamp should not be touched with the module s glass Use appropriate bolted connections as per clamp manufacturer s instructions Fo...

Page 18: ... Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging A minimum of two o...

Page 19: ...ea Contact solarinfo lge com http www lg solar com LG Electronics Deutschland GmbH Alfred Herrhausen Allee 3 5 65760 Eschborn Germany Contact service solar lge de LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...