background image

11

Product Specifications

- Electrical and Mechanical Properties
(Rated electrical characteristics are within 10 percent)
Standard Test Condition(STC) : Irradiation 1,000W/m

2

, Cell temp. 25°C, AM1.5

Note : * Relative efficiency reduction by respect to irradiance

** MC4 formal name : PV-KST4 / 6II-UR, PV-KBT4 / 6II-UR

s

e

i

t

r

e

p

o

r

P

 

l

a

c

i

n

a

h

c

e

M

s

e

i

t

r

e

p

o

r

P

 

l

a

c

i

r

t

c

e

l

E

s

e

t

a

c

i

f

i

t

r

e

C

1

ri

M

odule Series

M

o

del

 Name

IEC61215 Ed.2, 

IEC 

61730,

Safety

 Class 

II, 

CE, 

ISO900

Pmax at 

STC

P

o

w

e

r T

o

lerance

V

o

c

 at 

STC

Isc at 

STC

Vmpp at 

STC

Im

pp at STC

*Efficiency

 Reduction

M

a

x. No.

 of 

modules 

in

se

r

es

M

ax. Sy

stem 

V

o

lta

g

e

Connector

Length

Wi

dth

Hei

g

ht

We

ig

h

t

W

%

V

A

V

A

%

V

mm

mm

mm

kg

g

L

GXXXN1C(

W)

-G

4

LG280N1C(W)-G4

Yes

280

3%

38.6

9.78

30.7

9.13

<2.0

20

1000

**

MC4

1640

1000

40

17.0

LG285N1C(W)-G4

Yes

285

3%

38.9

9.81

31.1

9.17

<2.0

20

1000

MC4

1640

1000

40

17.0

LG290N1C(W)-G4

Yes

290

3%

39.2

9.84

31.4

9.24

<2.0

20

1000

MC4

1640

1000

40

17.0

LG295N1C(W)-G4

Yes

295

3%

39.5

9.87

31.8

9.28

<2.0

20

1000

MC4

1640

1000

40

17.0

LG300N1C(W)-G4

Yes

300

3%

39.8

9.90

32.2

9.34

<2.0

20

1000

MC4

1640

1000

40

17.0

LG305N1C(W)-G4

Yes

305

3%

40.1

9.93

32.5

9.39

<2.0

19

1000

MC4

1640

1000

40

17.0

LG310N1C(W)-G4

Yes

310

3%

40.4

9.96

32.8

9.45

<2.0

19

1000

MC4

1640

1000

40

17.0

LG315N1C(W)-G4

Yes

315

3%

40.6

10.02

33.2

9.50

<2.0

19

1000

MC4

1640

1000

40

17.0

LG320N1C(W)-G4

Yes

320

3%

40.9

10.05

33.6

9.53

<2.0

19

1000

MC4

1640

1000

40

17.0

L

LG325N1C(W)-G4

Yes

325

3%

41.2

10.08

34.0

9.57

<2.0

19

1000

MC4

1640

1000

40

17.0

LG330N1C(W)-G4

Yes

330

3%

41.5

10.11

34.3

9.63

<2.0

19

1000

MC4

1640

1000

40

17.0

LG335N1C(W)-G4

Yes

335

3%

41.8

10.14

34.6

9.69

<2.0

19

1000

MC4

1640

1000

40

17.0

LG340N1C(W)-G4

Yes

340

3%

42.1

10.17

34.9

9.75

<2.0

19

1000

MC4

1640

1000

40

17.0

K-G4

LG280N1K-G4

Yes

280

3%

38.1

9.53

31.0

9.04

<3.0

20

1000

MC4

1640

1000

40

17.0

LG285N1K-G4

Yes

285

3%

38.5

9.57

31.3

9.11

<3.0

20

1000

MC4

1640

1000

40

17.0

LG290N1K-G4

Yes

290

3%

38.9

9.61

31.7

9.16

<3.0

20

1000

MC4

1640

1000

40

17.0

LG295N1K-G4

Yes

295

3%

39.3

9.66

32.1

9.21

<3.0

20

1000

MC4

1640

1000

40

17.0

LG300N1K-G4

Yes

300

3%

39.7

9.70

32.5

9.26

<3.0

20

1000

MC4

1640

1000

40

17.0

LGXXXN1

LG305N1K-G4

Yes

305

3%

40.1

9.74

32.9

9.28

<3.0

19

1000

MC4

1640

1000

40

17.0

LG310N1K-G4

Yes

310

3%

40.5

9.78

33.3

9.31

<3.0

19

1000

MC4

1640

1000

40

17.0

LG315N1K-G4

Yes

315

3%

40.6

9.82

33.7

9.35

<3.0

19

1000

MC4

1640

1000

40

17.0

LG320N1K-G4

Yes

320

3%

40.9

9.86

34.1

9.39

<3.0

19

1000

MC4

1640

1000

40

17.0

LG325N1K-G4

Yes

325

3%

41.2

9.90

34.5

9.43

<3.0

19

1000

MC4

1640

1000

40

17.0

LG330N1K-G4

Yes

330

3%

41.6

9.94

34.9

9.47

<3.0

19

1000

MC4

1640

1000

40

17.0

- Dimensions of Modules

Note :*Holder is for the convenient connection of junction box cable,but that does not warranty if it is broken

after installed.

LGXXXN1C(W,K)-G4

Cross-sectional drawings

Unit: mm / in.

Long side

frame

Short side

frame

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for LG N1C-G4 Series

Page 1: ...Monocrystalline Solar Module LGXXXN9C W G4 LGXXXN1C W K G4 Installation Instructions MFL69021104 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...ion 4 3 Electrical Installation 5 4 Mechanical Installation 6 5 Product Specifications 10 6 Disclaimer of Liability Disposal 12 7 Transporting and Storage 12 Date Version Remark Description of change 1 0 1st edition 2015 01 22 All manuals and user guides at all guides com ...

Page 3: ...t Deformation Occurrence of space Please use proper equipment connector wire and buttress for system configuration of the module It may result in damage or failure of the product Do not perform installation in rainy heavily windy or snowy days It may result in safety accident Do not make holes in the frame or glass of the module It may decrease the strength of the frame or break the glass Do not t...

Page 4: ...the roof or ground Before Installation Please carefully read this manual before installation Solar module installation should be performed by an authorized installer for the safety and maintenance of the system All installation instructions should be clearly understood before attempting installation Do not twist pull or scratch the cable attached to the solar module Do not touch the solar module w...

Page 5: ...Do not use panels of different electrical or physical configurations in the same system Match the polarities of cables and terminals when making the connections failure to do so may result in damage to the panel When reverse currents can exceed the value marked on the name plate a properly rated and certified over current device fuse or circuit breaker must be connected in series with each panel o...

Page 6: ...overing rated for the application The fire resistance of the solar module from LG Electronics is class C after ANSI UL790 The solar module is only IEC listed for use when its factory frame is fully intact Do not remove or alter the solar module frame Creating additional mounting holes may damage the solar module and reduce the strength of the frame Electrical Installation General Wiring LG Electro...

Page 7: ...hanical Installation Scene Refer to next page Mounting by using frame bolts holes Secure the solar module to the structure using the factory mounting holes Four M6 stainless steel bolts four nuts four spring washers and eight flat washers are recommended per solar module For rear loads 5400Pa modules should be fastened with four M8 stainless steel bolts four nuts four spring washers and eight flat...

Page 8: ...of long frame Clamping Range 100mm Clamping Range From module Edge to 270mm Clamping Range From module Edge to 120mm Center 100mm Center 100mm Use four clamps on the Short frame This method is not tested by IEC UL This installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind shield or d...

Page 9: ...e Clamping Range 250mm Clamping Range From module Edge to 270mm Clamping Range From module Edge to 120mm Center 100mm Center 100mm Use four clamps on the Short frame This method is not tested by IEC UL This installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop 2 Flat roof If installed with an additional stand such as wind shield or deflector LGX...

Page 10: ... modules in ser es Max System Voltage Connector Length Width Height Weight W V A V A V mm mm mm kg g LGXXXN9C W G4 LG270N9C W G4 Yes 270 3 36 7 9 86 28 9 9 35 2 0 22 1000 MC4 1480 1000 40 15 4 LG275N9C W G4 Yes 275 3 36 8 9 90 29 3 9 39 2 0 22 1000 MC4 1480 1000 40 15 4 LG280N9C W G4 Yes 280 3 37 0 9 94 29 7 9 43 2 0 22 1000 MC4 1480 1000 40 15 4 L LG285N9C W G4 Yes 285 3 37 1 9 97 30 1 9 47 2 0 2...

Page 11: ...4 Yes 320 3 40 9 10 05 33 6 9 53 2 0 19 1000 MC4 1640 1000 40 17 0 L LG325N1C W G4 Yes 325 3 41 2 10 08 34 0 9 57 2 0 19 1000 MC4 1640 1000 40 17 0 LG330N1C W G4 Yes 330 3 41 5 10 11 34 3 9 63 2 0 19 1000 MC4 1640 1000 40 17 0 LG335N1C W G4 Yes 335 3 41 8 10 14 34 6 9 69 2 0 19 1000 MC4 1640 1000 40 17 0 LG340N1C W G4 Yes 340 3 42 1 10 17 34 9 9 75 2 0 19 1000 MC4 1640 1000 40 17 0 K G4 LG280N1K G...

Page 12: ...eparately from the municipal waste stream 2 Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources ...

Page 13: ...All manuals and user guides at all guides com ...

Page 14: ...u Seoul 150 721 Korea Contact solarinfo lge com http www lg solar com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II G4 N IEC V1 EN 201501 All manuals and user guides at all guides com ...

Reviews: