AC Module System Installation Manual
Rev. 1.0
9 Product Specifications
DC Input
Parameter
Section
LG355A1C-A5
LG360A1C-A5
LG365A1C-A5
Power
Max.
355W
360W
365W
Tolerance
0% ~ 3%
Voltage
Voc
42.7V
42.7V
42.8V
Vmpp
36.3V
36.5V
36.7V
Tolerance
–5% ~ +5%
Current
Isc
10.78A
10.79A
10.80A
Impp
9.79A
9.87A
9.95A
Tolerance
–5% ~ +5%
Note : PV module was measured at STC (Standard Test Condition: Irradiation 1,000W/m
2
, Cell temp. 25℃(77℉),1.5AM)
AC Output
Parameter
Section
240VAC
208VAC
Power
Inverter Rated Continuous
320W
320W
Voltage
Nominal(Range)
240V (211V ~ 264V)
208V (183V ~ 229V)
Current
Nominal Output
1.33A
1.54A
Frequency
Nominal(Range)
60Hz (59.3Hz ~ 60.5Hz)
Power Factor(adjustable)
1/0.8 leading…0.8 lagging
CEC Weighted Efficiency
(California Energy Commission)
97%
96%
Max. Number of AC Modules
1)
12 EA
10 EA
Certification
DC module
UL1703, IEC61215, IEC 61730, Safety Class II
AC module
UL1741, IEEE1547, UL1741SA
FCC Part 15 Class B
IEEE 1547 (Default)
Parameter
Range
Clearing Time (s)
Phase Voltage
V < 50%
0.16
50% ≤ V < 88%
2.00
110% ≤ V < 120%
1.00
V ≥ 120%
0.16
Frequency
> 60.5 Hz
0.16
< 59.3 Hz
0.16
•
After the micro inverter got tripped by voltage or frequency abnormality, it takes about 5 min for the AC module
to operate.
•
If it got tripped by other reasons or it is connected with the utility after sunrise, it takes about 1 min for the AC
module to operate.
1) Refer to 3-12 Connecting Array of AC Modules to Distribution Panel regarding Maximum number of AC Modules.
9-1 AC module , LGXXXA1C-A5
99
Copyright © 2017 LG Electronics.