Symptom
Check Point
1. E CF
1. Check the air flow
2. Check the Connector
2. Check the PCB Fan motor voltage
Fan Motor
TEST MODE 1
Voltage [V]
CON7
4
th
pin & 6
th
pin
11.4~12.6V
CON7
2
nd
pin & 6
th
pin
Not 0V, 5V
CON5
1
st
pin & 4
th
pin
Not 0V, 5V
8-11. Condenser Fan Error (E CF)
CON7
CN1
CON201
CON2
CON1
CON3
CON5
CON6
CON7