Symptom
Check Point
1. Poor cooling in Fresh
food section
1. Check the sensor resistance
2. Check the air flow
3. Check the air Temperature
4. Check the R-Damper motor voltage
8-16. Poor cooling in Fresh food section
CON7 15
th
pin ~ 18
th
pin
Resistance [
Ω]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
Duct
Status
Air Flow
Windy
Air Temperature
Cold
Duct
Fan Motor
TEST MODE 1
Voltage [V]
CON7 12
th
pin ~ 14
th
pin
12V
CON7 16
th
pin ~ 14
th
pin
0V<Voltage<5V
CON7 10
th
pin ~ 14
th
pin
0V<Voltage<5V
CON6
CON1
CON201
CON5
CON7
CON2 CON3
R-Sensor
F-Fan motor