Poor cooling in Fresh food section
1
Check the sensor resistance.
7
Explain to customer
CON5
18
th
pin ~ 17
th
Pin
Resistance [
]
23ºF / -5ºC
38k
32ºF / 0ºC
30k
41ºF / 5ºC
24k
50ºF / 10ºC
19.5k
59ºF / 15ºC
16k
2 Reset the unit and
Input Test1 Mode
(Push the button 1 time)
3
Open the fresh food door and
Check the air flow Damper?
No
Yes
Check the
damper
Go to 5
4
Check the air temperature.
Is it cold?
No
Yes
Check the
Compressor
and sealed
system
5
Check the Fan Motor voltage
Is Fan Motor voltage right?
Yes
Replace
Main PCB
No
6
Check the Fan Motor voltage
Is Fan Feed Back voltage 0V, 5V?
No
Change the
motor
Yes
Go to 7
TEST MODE 1
Voltage [V]
CON3 8
th
pin ~ 5
th
Pin
12V
CON5 7
th
pin ~ 5
th
Pin
0V<Voltage<5V
TEST MODE 1
Voltage [V]
CON5 6
th
pin ~ 5
th
Pin
0V<Voltage<5V
1
2
3
4
- 57 -
Summary of Contents for LFXS26973 series
Page 7: ... 7 ...
Page 77: ... 77 11 3 Door Heater Assembly 1 9 2 2KΩ ...