48
MAINTENANCE
2
3XOOWKHZDWHU¿OWHUGRZQZDUGDQGSXOORXW0DNH
VXUHWRURWDWHWKH¿OWHUGRZQFRPSOHWHO\EHIRUH
pulling it out of the manifold hole.
3
5HSODFHZLWKDQHZZDWHU¿OWHU
7DNHWKHQHZZDWHU¿OWHURXWRILWVSDFNLQJDQG
remove the protective cover from the o-rings.
:LWKWKHZDWHU¿OWHUWDEVLQWKHKRUL]RQWDOSRVLWLRQ
SXVKWKHQHZZDWHU¿OWHULQWRWKHPDQLIROGKROH
until it stops.
4
5RWDWHWKHZDWHU¿OWHUXSLQWRSRVLWLRQDQGFORVH
the cover. The cover will click when closed
correctly.
5
$IWHUWKHZDWHU¿OWHULVUHSODFHGGLVSHQVH
JDOORQVRIZDWHUÀXVKIRUDSSUR[LPDWHO\
minutes) to remove trapped air and contaminants
from the system.
NOTE
x
Do not dispense the entire 2.5 gallon amount
continuously. Press and release the dispenser pad
for cycles of 30 seconds ON and 60 seconds OFF.
x
.HHSWKHZDWHU¿OWHUE\SDVVSOXJ<RX0867XVH
WKHZDWHU¿OWHUE\SDVVSOXJZKHQDUHSODFHPHQW
ZDWHU¿OWHUFDUWULGJHLVQRWDYDLODEOH
6
$IWHUFKDQJLQJWKH¿OWHUSUHVVDQGKROGWKH
Water Filter
button for three seconds to reset the
indicator light.
CAUTION
x
DO NOT operate the refrigerator without a water
¿OWHURUZDWHU¿OWHUE\SDVVSOXJLQVWDOOHG
NOTE
7RSXUFKDVHDUHSODFHPHQWZDWHU¿OWHU
x
Visit your local dealer or distributor
x
6HDUFKXVLQJZDWHU¿OWHURQ
lg.com
x
Use replacement cartridge:
ADQ36006101
For further assistance, call:
1-800-243-0000 (USA)
1-888-542-2623 (Canada)