- 27 -
0
Short
Open
Normal
Change the sensor
Replace the refrigerator
Check the Temp and
resistance (Table-2)
Result
SVC Action
8-2 Refrigerator Sensor Error (Er rS)
No
1
2
Checking flow
Check for a loose connection.
Check the White to White at
CON7 on the main PCB
Result & SVC Action
<Temperature table-2>
(1) To (2)
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
The sensor is determined by
the temperature.
For example, 30
indicates 32°F.
<CON7>