8-4 TROUBLESHOOTING
PROBLEM
INDICA
TED BY
CHECK
CHECKING METHOD
CAUSE
SOLUTION
Power source
1.
The whole DISPLA
Y
1. FREEZER/
Check if freezer or
Power source is poor
.
Check outlet voltage.
is poor
.
LED/SEVEN SEGMENT
REFRIGERA
T
OR.
refrigerator door is open
DISPLA
Y
is of
f.
and check display
.
2.
DISPLA
Y LED/
2. If lamp is dim.
Check visually
.
Applied voltage error
.
Use boosting transformer
.
SEVEN SEGMENT
3. The connection of
Check connection of
connector connection
Reconnect connector
.
DISPLA
Y operates
the main PWB
connector
.
is poor
.
abnormally
connector
.
T
ransformer fuse is open.
Replace transformer
.
Cooling is poor
.
No cooling.
1. If the compressor
Use T
est Mode1
Compressor locked or
Replace compressor
.
operates.
(forced cooling).
blocked.
If less than 7 minutes pass
OLP
, PTC, or
Replace OLP
, PTC.
after compressor shuts of
f,
compressor are failed.
Replace main PWB.
don’t press the key and
wait.
Connection wire is defective.
Check the connection of the
black wire of the main PWB
connector (CON1).
2. If refrigerant is leaking.
Measure the amount of frost
Refrigerant leakage.
Replace the leaking part and
.
sticking on evaporator
replace any lost refrigerant.
and the surface temperature
of the condenser pipe.
Freezer
1. If fan motor
Use T
est Mode 1
Fan motor is defective.
Replace the fan motor
.
temperature is
operates.
(forced cooling).
incorrect
Connection wire is defective.
Refer to 8-2-4. 2 and check
2. If defrosting
Check the amount of frost
Defrosting is poor
.
See
DEFROSTING
is normal.
sticking on the
evaporator
.
is poor
,
page 35.
3. If sensor
Check the resistance
Sensor resistance is
Replace sensor
.
is normal.
of the refrigerator
incorrect.
sensor
.
4. Gasket seal incorrect.
Check the seal when
Door liner damaged.
Replace door liner
.
the door is closed.