background image

1

Caution for safety

All electrical work should be undertaken by a suitable qualified and competent person. 

This electrical appliance must be installed according to this instruction in order to avoid damages.
Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer
cannot be held liable for unauthorised work.

Warning: Ensure power is not supplied to the appliance while installation or repair work is

being carried out.

Possible combinations (Oven and Hob)

The LG ovens with integrated hob controls (=cooker or underbench ovens) may only be combined
with hobs and their respective control units as specified by LG Electronics for use with that oven.
Contact your dealer or the relevant LG Electronics Service Department for further information on
suitable combinations.

Power supply cord (not supplied)

Contact your dealer/supplier or the relevant LG Electronics Service Department for further
information on a suitable power supply cord for the cooker.
The 

voltage and rated load

are given on the data plate, visible when the oven door is open. For

connecting the power supply cord, follow the connection diagram (fig-2D).

Important: The yellow-green wire for earth connection (at the appliance) must be minimum

10 mm longer than the other wires

WARNING: THIS APPLIANCE MUST BE EARTHED.

[fig-1B]

[fig-1D]

[fig-1C]

min. 600

min.556

min. 560

50

100

100

R

P

Q R

min. 50

50

70

320

120

100

100

571

583

21

546

556

594

594

grip hole

[fig-1A]

Summary of Contents for LE641152

Page 1: ...Built In Cooker Installation Instructions LE641152 LE641122 LE641150 LE641120 LE621120 LE621100 Please read the instructions before installing this product P no MFL06218407 ...

Page 2: ... units as specified by LG Electronics for use with that oven Contact your dealer or the relevant LG Electronics Service Department for further information on suitable combinations Power supply cord not supplied Contact your dealer supplier or the relevant LG Electronics Service Department for further information on a suitable power supply cord for the cooker The voltage and rated load are given on...

Page 3: ...secure it to the side walls of the housing unit through the holes in the trim fig 2B Reconnect the power supply to the isolator switch Electrical connection All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with national and local safety regulations WARNING THIS APPLIANCE MUST BE EARTHED The voltage and rated load are given on the data plate...

Page 4: ...n gap of 5 mm is required between the oven top rim and the hob lower rim and a ventilation gap of 5 mm is required between both oven side rims and the cabinet see fig 2B Important All ventilation openings intake and outtake must not be closed at any time when operating the oven Requirements for the housing unit cabinet The requirements for the heat resistance of the material used for housing unit ...

Page 5: ...4 Memo ...

Page 6: ...5 Memo ...

Page 7: ...6 Memo ...

Page 8: ...Printed in korea ...