- 23 -
- 23 -
ERROR MESSAGE
POSSIBLE CAUSE
REMEDY
FOR ERROR OCCURRENCE
The Inlet Valve is troubled.
The Controller is troubled.
The Inlet Water Temperature is
very high. (over 194
)
Wiring connection is OK?
The Thermistor is OK?
Wiring connection is OK?
The Impeller of Washing Pump is
locked.
The rotor of Washing Motor is
locked.
The Blade is locked.
Check the temperature. (Test Mode)
If the temperature is displayed,
adjust the Inlet Water
Temperature to 120
.
If the temperature is not
displayed,
check the wiring connection.
check the electric resistance
of Thermistor.
(11~14k
at 77
)
Replace the PCB.
Replace the Inlet Valve.
Repair or replace the Controller.
Excessive water is sup-
plied than normal water
level.(Automatically drain
Pump operated.)
EXCESS ERROR
displayed
Condition
The resistance of ther-
mistor not normally out put.
THERMAL ERROR
displayed
Condition
Check the wiring connection.
Replace the cause of restriction.
Replace the Washing Motor.
Replace the PCB.
The Motor is working
abnormally.
MOTOR ERROR
displayed
Condition
The Circuit of Heater is troubled.
The Thermistor is troubled.
The Heater is shorted.
The Relay Circuit is troubled.
Repair the Circuit of Heater.
Replace the Thermistor.
Replace the Heater.
Repair the Relay Circuit..
The water is not heated or
the temperature in the Tub
is overheated to over 194ßF
HEATER ERROR
displayed
Condition
Summary of Contents for LDS4821
Page 5: ... 6 LDS4821 serise 3 WIRING DIAGRAM ...
Page 11: ... 12 6 PROGRAM CHART SCHEMATIC DIAGRAM Program chart LDS 4821 Series ...
Page 35: ... 36 36 EXPLODED VIEW F001 M100 M210 M105 M261 M266 M260 A160 A130 A040 A003 F101 E005 E010 ...
Page 38: ... 39 K260 K252 K254 K262 K200 K230 K201 K006 K251 K203 EXPLODED VIEW PANEL ASSEMBLY 39 ...
Page 41: ... 42 MEMO ...
Page 42: ... 43 MEMO ...
Page 43: ...P No MFL37554804 ...