- 10 -
4-5. TEST MODE
CHECK PROGRAM
BUTTON
The number of
pushing button
Top
Display
Load and Checking points
Door open/
closed
Rinse + Spray
+ Power
Soak
Power Scrub
Normal
Steam Delicate
Quick
Rinse Only
Steam
Rinse
Spray
Half Load
Delay start
�
Normal water level : 270 ~ 275
�
Pure water : more than 130
�
H: High water level / L: Low water level
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
2 TIME
3 TIME
4 TIME
5 TIME
6 TIME
7 TIME
8 TIME
9 TIME
10 TIME
11 TIME
12 TIME
13 TIME
14 TIME
15 TIME
Steam generator
Temp( )
0n:H1
0n:33
�
Frequency
0n:35
0n:36
0n:37
0n:38
Sump Temp( )
�
Soil level
0n:3b / Motor RPM
Steam generator
Water level
0n:3d
0n:3E
0n:3F
(RPM, Frequency)
0n:3H/0U:00
00:00
11:11
22:22
33:33
44:44
55:55
66:66
77:77
88:88
99:99
Steam generator
Thermistor
Steam generator
Heater (for 1.2 sec)
Drain Pump
Inlet Valve
Dispenser
Sump Heater
(for 10 sec)
Fan Motor
Sump Thermistor
Soil sensor
Wash Pump
�
H170
↑
/L170
↑
Lower Nozzle
(Vario)
Upper Nozzle
(Vario)
W/Pump+Vario+
Heater (for 1min)
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs
All LEDs are lighting
Both
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Both
Closed
Both
Closed
Closed
Closed
Closed
Closed
Both
Both
Closed
Both
Closed
Closed
Closed
※
Steam Demo mode : Steam + Power
Summary of Contents for LDF9810BB
Page 1: ...P No MFL37554802 ...
Page 6: ... 5 1 LDF9810 series 3 WIRING DIAGRAM ...
Page 13: ... 12 6 PROGRAM CHART SCHEMATIC DIAGRAM LDF 9810 Series ...
Page 57: ... 56 MEMO ...
Page 58: ... 57 MEMO ...