![LG LDC22720 Series Service Manual Download Page 22](http://html.mh-extra.com/html/lg/ldc22720-series/ldc22720-series_service-manual_1902984022.webp)
7-2-4 Load / Buzzer Drive & Open Door Detection Circuit
1. Load Drive Condition Check
2. Fan motor driving circuit (freezing compartment fan)
- 22 -
LOAD TYPE
COMP
NO.14
NO.11
NO.13
1V or below
12V
DEFROSTING
HEATER
LAMP
TCM
POWER MODE
(OPTIONAL)
Measurement Location (IC6)
Condition
ON
OFF
part
part
part
MOTOR OFF
2V or less
0V
5V
MOTOR ON
13V~15V
0V
2V~3V
a
b
c
NO.12
1. This circuit makes standby power 0 by cutting off power supplied to Iss inside of the fan motor in the fan motor OFF.
2. This is a circuit to perform a temporary change of speed for the fan motor and applies SC voltage up to 7.5V - 16V to
motor.
3. This circuit prevents over-driving the fan motor by cutting off power applied to the fan motor in the lock of fan motor
by sensing the operation RPM of the fan motor.