- 9 -
4.3 TEST MODE
CHECK PROGRAM(START IN THE STATE OF THE CLOSED DOOR)
※
CHECK MODE
BUTTON
BUTTON
OPERATION
P Half Load
P Rinse
Display Water Supply Frequency
Display Inner Temperature
The number of
pushing button
DISPLAY
Load and Checking points
Door
Micro S/W must be ON to operate HEATER
Half Load + Rinse
+ POWER S/W
Delay Start KEY
Program KEY
Half Load KEY
Rinse KEY
Start/Pause Key
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
1 TIME
2 TIME
3 TIME
4 TIME
5 TIME
6 TIME
7 TIME
8 TIME
9 TIME
10 TIME
11 TIME
n : 1H ?
?
U100
11 : 11
12 : 22
13 : 33
14 : 44
n : 11
n : 12
n : 13
Frequency
n : 15
n : 16
Temperature
n : 18
n : 19
n : 1A
n : 1b
All LEDs are lighting
closed
All LEDs are lighting
not concerned
not concerned
not concerned
not concerned
All LEDs are lighting
All LEDs are lighting
All LEDs are lighting
None
In
closed
closed
not concerned
closed
closed
closed
closed
closed
closed
closed
closed
closed
Washing Motor
Drain Pump
Inlet Valve
Dispenser
Heater(for 10 sec.)
Fan Motor
None
Lower Nozzle
Upper Nozzle
Operate C1 mode(for 1 min.) ?
?
Drain(for 42 Sec.) ?
?
Supply water
Intensive
Eco 65
?
Eco 50
?
Gentle
Quick
Pre-wash
Wash
Rinse
Dry
12 TIMEPower OFF
AUTO OFF
Summary of Contents for LD-2040M1
Page 2: ... 3 ...
Page 10: ... 10 5 WIRING DIAGRAM ...
Page 11: ... 11 6 PROGRAM CHART SCHEMATIC DIAGRAM ...
Page 32: ... 32 A276 10 EXPLODED VIEW ...
Page 36: ... 36 M210 F072 M230 A130 A131 M250 M023 M280 M270 M260 A030 A040 EXPLODED VIEW BASE ASSEMBLY ...
Page 38: ... 38 MEMO ...
Page 39: ... 39 MEMO ...
Page 40: ...P No 3828DD3007M ...