- 31 -
1. If the end drain hose does not fit to the drain line, use a piece of rubber connector (not supplied)
that must be resistant to heat and detergent and may be obtained from a plumbing shop.
2. There are 2 typical connections as shown in Figure A, B
Fig. A
Fig. B . Drainage connection-stand pipe
¥ The recommended methods of drain hose connection must be adhered to within the areas of Water Board
Authority. Several other options are commonly used outside this area and local council or plumbers should
be able to advise of these.
¥ The S trap spigot must be drilled out cleanly and free of obstruction to its maximum internal diameter, if
used for drainage.
¥ To prevent syphoning, one of the following instruction methods must be followed :
■
When the drainage hose is connected to a sink S trap or waste disposal unit, the hose must be looped up
to the under side of the bench top and secured.
■
When the drain hose is connected to a separate stand pipe, it is essential that an air tight connection is
made. Refer to Fig. B
Step 5 : DRAIN LINE CONNECTION
3828DD3007H(S/M)
2008.2.18
4:25
PM
페이지31
001
GateRip_A3
Summary of Contents for LD-1415M
Page 2: ... 3 ...
Page 11: ... 11 5 WIRING DIAGRAM ...
Page 12: ... 12 6 PROGRAM CHART SCHEMATIC DIAGRAM ...
Page 33: ... 33 10 EXPLODED VIEW ...
Page 37: ... 38 M230 A130 A131 A276 M250 M023 M280 M270 M260 A030 A040 EXPLODED VIEW BASE ASSEMBLY ...
Page 39: ...P No 3828DD3007H ...