Installation
Service Manual
23
More than
30cm
Fence or
obstacles
More than 70cm
More than 50cm
More than
30cm
More than
30cm
Sunr
oof
More than
30cm
Fence or
obstacles
More than 70cm
More than 50cm
More than
30cm
More than
30cm
Sunr
oof
More than 50cm
(Service space)
1.2 Outdoor Unit
• If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from
the condenser is not restricted.
• Ensure that the space around the back is more than 30cm and sides is more than 30cm. The front of the unit
should have more than 70cm of space.
• Do not place animals and plants in the path of the warm air.
• Take the air conditioner weight into account and select a place where noise and vibration are minimum.
• Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
• Rooftop Installations : If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the
roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop
mounting.
1. Select the best location
Install the air conditioner in the location that satisfies the following conditions.
1.1 Indoor Unit
• There should not be any heat source or steam near the
unit.
• There should not be any obstacle to the air circulation.
• A place where air circulation in the room will be good.
• A place where drainage can be easily obtained.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, or other obstacles.
• The indoor unit must have sufficeient maintenance
space.
Unit:cm
Ceiling
Ceiling Board
Ceiling Board
30 or more
Abo
ve
250
400 or less
100
or more
50 or
more
50 or
more
30 or less
Floor
Installation