- 43 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
n
The problem of missing the connector (SUB PCB ASSY)
Connectors
CN-UVW
CN-IPM
Condition
OPEN
OPEN
• Stop compressor.
CN-Gate 1, 2
OPEN
• Malfunctions inverter circuit
• The operation LED blink 9 times.
• Malfunctions inverter circuit.
• Stop compressor and outdoor fan.
• The operation LED blinks 8 times.
Problem (error mode)
n
The problem of missing the connector (OUTDOOR MAIN PCB ASSY)
Connectors
CN-POWER
CN-AC
CN-DC
CN-IPM
CN-GND
CN-FAN
CN-TH
CN-COMP
Condition
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN/SHORT
OPEN/SHORT
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 10 times.
• Malfunctions inverter circuit.
• Stop compressor and outdoor fan.
• The operation LED blinks 8 times.
• Malfunctions EMI /EMS
CN-Gate 1, 2
OPEN
• Malfunctions inverter circuit
• The operation LED blinks 9 times.
• Malfunctions fan.
• The operation LED blinks twice.
• The LED01K blinks 10 times.
• Continue Comp. operation.
(when the discharge pipe TH opens)
• Stop Comp. operation
(when the discharge pipe TH shorts)
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
• The operation LED blinks 10 times.
Problem (error mode)
Summary of Contents for LBNG3061YL
Page 50: ...P NO 3828A20097R JULY 2008 ...