1. Specification
Nominal Capacity
Cooling
kW
(Min~Rating~Max)
Btu/h
Heating
kW
Btu/h
Nominal Input
Cooling
kW
(Min~Rating~Max)
Heating
kW
Testing Combination
Running Current(Rating)
Cooling
A
Heating
A
Starting Current
Cooling/Heating
A
Power Supply
Ø / V / Hz
Power Supply Cable(Outdoor)
No. x mm
2
Power and Transmission Cable(Outdoor to Indoor or Outdoor to BD)
No. x mm
2
Power and Transmission Cable(BD to Indoor)
No. x mm
2
Dimensions
W x H x D
mm(inch)
Net Weight
kg(lbs)
Max. Number of Connectable Indoor Units
Compressor (#1)
Type
Qty x Model
Motor type
Oil charge volume
cc
Oil Type
Compressor (#2)
Type
Qty x Model
Motor type
Oil charge volume
cc
Oil type
Compressor (#3)
Type
Qty x Model
Motor type
Oil charge volume
cc
Oil type
Refrigerant
Cycle A Charge (at 7,5m)
g(oz)
Cycle B Charge (at 7,5m)
g(oz)
Type
Control
Additional Refrigerant Charge
g/m(oz/ft)
Heat Exchanger
(Rows x Column x FPI) No.
Defrosting Method
Fan
Capacitor
μF/Vac
Drive
Discharge Direction(Side/Top)
Air Flow RateNo. of Fan
CMM(cfm)
Sound Level(H/L)
Sound Pressure
dB(A)+3
Piping Connections
Liquid(Cycle A)
mm(inch)
Gas(Cycle A)
mm(inch)
Liquid(Cycle B)
mm(inch)
Gas(Cycle B)
mm(inch)
High Pressure Gas
mm(inch)
Max. Interunit
Total Piping
m
Piping Length
Main Piping
m
Total Branch Piping
m
Each Branch Piping
m
Max. Elevation
Outdoor Unit~Indoor Unit
m
Difference
Indoor Unit~Indoor Unit
m
Operation Range
Cooling
°C(°F)
(Outdoor)
Heating
°C(°F)
3.52~28.72
12,000~98,000
-
-
2.5~9.75
-
Cycle 1 : LMNC1 LMNC36GTNA0
Cycle 2 : LMNC2 LMNC242D5A0
8.5~30.5
-
-
3/220/60
4 x 13.3 (Including Earth)
4 x 0.75 (Including Earth)
4 x 0.75 (Including Earth)
1,280 x 1,520 x 730 (50.4 x 59.8 x 28.7)
260 (551)
8
Rotary
2 x QP348RAA
Single Phase Induction Motor
1,130
NM56 or SUNISO 4GSI
Rotary
2 x QP348RAA
Single Phase Induction Motor
1,130
NM56 or SUNISO 4GSI
-
-
-
-
-
4,300 (151.9)
4,300 (151.9)
R22
EEV / Short tube
Ø12.7 : 20(0.2) / Ø15.88 : 30(0.3) / Ø19.05 : 50(0.5)
(2R x 14C x 17) x 2 + (1R x 28C x 17) x 2
Reversing Cycle
10/370
Direct Drive
Top
53x2 (3,179)
60/60
9.52(3/8)
19.05(3/4)
9.52(3/8)
19.05(3/4)
-
110
50
60
15
45
10
21 (69.8) ~ 54 (129.2)
-
L8UC100BFA3/ L8UC100BFE3
Outdoor Unit
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80,6°F) DB/19°C(66,2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75,2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44,6°F) DB/6°C(42,8°F) WB
Piping Length - Interconnecting Piping Length 7,5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Conversion Formula
kW = Btu/h
×
0.0002931
cfm = CMM
×
35.3