4.7 USB
USB Initial sequence of L705iX is :
USB connected to L705iX power on
→
USB_VBUS(Q301 PIN4) go to 5V
→
USB_D+ go to 3.3V
(D300 PIN1)
→
USB_VP and USB_VN is triggered
→
USB work.
Start
Q301 PIN4 is 5V?
USB_D+ is 3.3V?
Change the Main board
Check Q301
Check D300
NO
YES
YES
NO
Cable is inserted?
YES
Insert cable
NO
Power is on?
YES
Go to power on trouble shooting
NO