12
Room Air Conditioner
Operation
Feature
Insulation Resistance Test
About the Controls of the Air Conditioner
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
1. Unplug the power cord and connect a jumper between 2 pins (black and white).
2. The grounding conductor (green or green and yellow) is to be open.
3. Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part
on the equipment at all positions [except Off] of the ROCKER SWITCH.
4. The value should be over 1 M
Ω
.
Operation
Auto
Swing
Power
Temp
Fan Speed
Timer
Mode
CAUTION: The Remote Controller will not function properly if strong
light strikes the sensor window of the air conditioner or if there are
obstacles between the Remote Controller and the air conditioner.