15
Connecting Alarm Device
Alarm terminals are used to connect the alarm (relay)
devices such as sensors, door switches, etc.
Connect the alarm (relay) device to the alarm (relay) output
terminal. Alarm signal outputs at an event occurrence.
TRX -
TRX +
TRX -
TRX +
Alarm (Relay)
Device
Contact Ratings
•
Maximum load current is
±130 mA.
•
Do not connect any
system or device that has
over 40 Vp-p bias voltage
on the contact terminal.
ALARM
COM
Equivalent
Diagram
Note:
Use a relay unit if the voltage or current of the
connected device exceeds the ratings.
Connections