4. TROUBLE SHOOTING
- 45 -
(3) Checking RX I/Q
U501
C529
C510
C513
0.1uF
C529
C510
39p
39p
VBAT
4
VCC_BBI
VCC_BBQ
24
VCC_FE
1
17
VCC_REF
12
VCC_TXVCO
VDD
13
VLDO1
15
16
VLDO2
VLDO3
9
REFINB
21
REF_OP
28
RX1800
RX1800B
27
26
RX1900
RX1900B
25
32
RX850
RX850B
31
30
RX900
RX900B
29
6
SCLK
SDATA
5
SEN
7
TXOP_HI
11
10
TXOP_LO
VAFC_NC
18
14
U501
AD6548
EUSY0280101
33
GND
2
I
IB
3
8
NC
23
Q
QB
22
REFIN
20
19
IN
QN
QP
IP
TEST POINT
CIRCUIT
WAVEFORM
Redownload software and calibration again
Similar?
No
Replace U501
Yes
No
Check C510, C529.
Check if there is any
Major difference
Refer to graph 4.2.3
Graph 4.2.3
Figure 4.2.3
CHECKING FLOW