Installation Manual
5
Installation of Indoor, Outdoor Unit
Installation of Indoor, Outdoor Unit
1. Selection of the best location
1) Indoor unit
•
There should not be any heat source or steam
near the unit.
•
There should not be any obstacles to prevent
the air circulation.
•
A place where air circulation in the room will be
good.
•
A place where drainage can be easily obtained.
•
A place where noise prevention is taken into
consideration.
•
Do not install the unit near the door way.
•
Ensure the spaces indicated by arrows from the
wall, ceiling, or other obstacles.
2) Outdoor unit
•
If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure that
heat flow from the condenser is not restricted.
•
Ensure that the space around the back and
sides is more than 300mm. The front of the unit
should have more than 700mm of space.
•
Do not place animals and plants in the path of
the warm air.
•
Take the weight of the air conditioner into
account and select a place where noise and
vibration are minimum.
•
Select a place where the warm air and noise
from the air conditioner do not disturb neighbors.
More than
200mm
More than
1200mm
More than
200mm
R
R
More than
200mm
More than
200mm
(Ceiling installation)
(Floor/Wall installation)
More than
300mm
More than 300mm
More
than 600mm
More than 600mm
More than
700mm
VB CHASSIS