![LG HB6422BGF Installation And Operating Instructions Manual Download Page 8](http://html.mh-extra.com/html/lg/hb6422bgf/hb6422bgf_installation-and-operating-instructions-manual_209664008.webp)
Instructions for the installer
4. GAS CONNECTION
Connection to the gas mains may be made with a rigid copper pipe
or with a flexible pipe and conforming to the provisions defined by
standard regulations in force.
To facilitate connection, fitting A on the rear of the appliance may be
adjusted laterally. For this purpose, loosen hexagon nut B, turn
fitting A to the desired position, and retighten hexagon nut B
(tightness is ensured by a biconical brass ring). Use a soapy
solution to check for proper tightness. Never use a free flame.
The hob has been inspected for G20 (2H) natural gas at a pressure
of 20 mbar. For use with other types of gases, see Section “5.
ADAPTATION TO DIFFERENT TYPES OF GAS”. The gas intake
fitting is
1
/
2
gas external threaded (ISO 228-1).
8
The flexible pipe has to be installed so that pipe length does not
exceed 1.5 meters of maximum extension. Make sure that the pipes
do not touch any moving parts or become damaged.
Connection with rigid copper pipe:
the connection to the gas mains must
not provoke stress of any kind on the
hob.
Connection may be made by using
biconical adapter D with insertion of
gasket C (supplied).
Connection with flexible pipe:
use
only flexible pipes conforming to
standard regulations in force, inserting
gasket C (supplied) between fitting A
and flexible pipe E.