7-1-10 ERROR DIAGNOSTIC MODE
1. The error diagnostic mode allows the SVC when a fault that may affect the performance of the product occurs while
operating the product.
2. Even if the function control button is pushed when an error occurs, the function will not be performed. However, the
recognition tone (beep~) sounds.
3. When the error is cleared while the error code is displayed due to a fault, the appliance returns to the normal condition
(Reset).
4. The error code is displayed by the refrigerator temp indication LED on the display of the refrigerator while the remaining
LEDs are off.
- 19 -
Error Code
Display
NO
Error
Error Code
Cause
State of Operation with Error
Display
Comp
Cooling fan
Defrosting heater
1
2
3
4
5
Faulty refrigerator
(R) sensor
Faulty defrosting
sensor
Faulty Room
temperature sensor
(in the main PCB)
Defrosting failure
Failure of
communication
(LCD MODEL
ONLY)
r
d
when checking
LED, the error
code display all off
H
C
Cut or short-circuited wire of
refrigerator sensor
Cut or short-circuited wire of
defrosting sensor
Cut or short-circuited wire of
intake air temperature sensor
Cut or disconnected wire of
defrosting heater or temperature
fuse(indicated at least 4 hours
later after the error occurs)
Connection between main PCB
and display PCB. Snapping or
short-circuit of L/wire
transmission between main
PCB and display PCB. Poor TR
and receiving part.
15 min ON/
15 min OFF
standard
RPM
standard
RPM
standard
RPM
standard
RPM
standard
RPM
No defrosting
Summary of Contents for GR-S642
Page 33: ...7 5 MAIN PWB ASS Y AND PARTS LIST 7 5 1 MAIN PWB ASS Y 33 ...
Page 34: ...7 5 2 REPLACEMENT PARTS LIST 34 LED MODEL ...
Page 35: ... 35 LCD MODEL ...
Page 36: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 36 LED MODEL ...
Page 37: ... 37 LCD MODEL ...
Page 38: ...7 6 PWB DIAGRAM 7 6 1 PWB ASSEMBLY MAIN LED MODEL 38 ...
Page 39: ... 39 ...
Page 40: ...7 6 2 PWB ASSEMBLY MAIN LCD MODEL 40 ...
Page 41: ... 41 ...
Page 42: ...7 6 3 PWB ASSEMBLY DISPLAY LCD DISPLAY 42 ...
Page 43: ... 43 ...