39
Pin5
Pin6
Is the resistan6e value
between pins 6(BL/WH) and
5 (BN)ofCON3 like as
below?
Is the resistance value
of Fuse - Mlike as below?
Normal
Pin5 To Pin6
Test Point
180 ~ 230
Ω
Result
Is the resistance value of
heater like as below?
Is the resistance value of
DEF- sensor like as below?
It depends on the
temperature.
Explain to the customer!
: It can be occurred, when the gasket is not
stuck to product or when you put the high
temperature loads (hot foods) a lot
in the product.
Resistance
Replace
Heaters
No
Replace
DEF-sensor
No
Yes
No
Replace
Fuse-M
No
Yes
(1) To (2)
Test Point
230 ~ 260
Ω
Result
Heater Resistance
-30
℃
-20
℃
-10
℃
0
℃
Test Point
129.3
㏀
76.96
㏀
47.34
㏀
30
㏀
Result
10
℃
20
℃
30
℃
40
℃
Test Point
19.53
㏀
13.03
㏀
8.896
㏀
6.201
㏀
Result
Defrost Sensor Resistance
(1) To (2)
Test Point
0 ~ 0.5
Ω
Result
Open or Short of Fuse - M
Yes
Yes
(1) BL
(2) BN
(1) (2)
(1) BO
(2) BO