2. Description of Function
2-1. Funnction of Temperature Selection
* The temperature can vary ±3 °C depending on the load condition.
*( ) : 127V/60Hz, 110~115V/60Hz, 115V/60Hz Rating ONLY.
*< > : TAIBEI
1. When power is initially applied or reapplied after power cut, “Medium” is automatically selected.
2. When the temperature selection switch in the freezer and refrigerator compartments is pressed, the light is on in the
following sequence:
"Middle"
"Middle Strong" "Strong"
"Weak" "Middle Weak"
3. The temperature setting condition of freezer and refrigerator compartments shall not be indicate in the standard model
(GC-L207) when refrigerator or home bar door is closed.
MICOM FUNCTION
- 15-
Division
Power Initially On
1st Press
2nd Press
3th Press
4th Press
Type-2
(Bar-LED)
Change
of
Indication
Lamp
Temperature
Control
Middle
Middle Strong
Strong
Weak
Middle Weak
-19 °C
(-18 °C)
<-19 °C>
3 °C
<2 °C>
1.5 °C
<1 °C>
0 °C
<0 °C>
6 °C
<4.5 °C>
4.5 °C
<3 °C>
-21 °C
(-21 °C)
<-21 °C>
-23 °C
(-22 °C)
<-22 °C>
-15 °C
<-16.5 °C>
-17 °C
<-18 °C>
Freezer
Control
Refrigeration
Control
Summary of Contents for GR-L196TLQA.CPLQGSF
Page 23: ...EXPLATION FOR MICOM CIRCUIT 32 GC P L207 88 LED GC P L207 Bar LED GC P L207 Dot LED ...
Page 28: ...1 5 Temperature sensing circuit EXPLATION FOR MICOM CIRCUIT 28 GC L207 Bar LED F C A B D ...
Page 32: ...EXPLATION FOR MICOM CIRCUIT 50 GC P L207 Bar LED GC P L207 Dot LED b a e d b a e d ...
Page 38: ...EXPLATION FOR MICOM CIRCUIT 62 GC P L207 Bar LED ...
Page 39: ...EXPLATION FOR MICOM CIRCUIT 68 GC P L207 Bar LED ...
Page 40: ...EXPLATION FOR MICOM CIRCUIT 69 GC P L207 Bar LED ...
Page 41: ... GC P L207 Bar LED EXPLATION FOR MICOM CIRCUIT 78 ...
Page 42: ...EXPLATION FOR MICOM CIRCUIT 79 PWBASSEMBLY DISPLAY ...
Page 49: ...CIRCUIT 94 GC P L B C207 Bar LED The circuit has been only applied to voltage except 220v ...
Page 100: ......