MICOM Function and Description of Circuit
7) Operation in Response to Ambient Temperature
The storage senses the ambient temperature and adjusts the temperature in the compartments
accordingly. This keeps the storage from being too cold or too warm because of seasonal variations
and maintains exact temperatures in the compartments.
8) Sequential Operation of Components
Components (Compressor, 3-way Valve, Left/ Right Ripening Heater and Condensation Heater) are
operated in a specific order to prevent damage, noise, and electrical overload caused by
simultaneous operation of all parts when the unit is started and after completing the self-test routine.
❇
Operation order may slightly vary depending on temperature setting.
When returning normal
status in test mode
Initial P
o
wer
-up
Temperature of Left or
Right sensor is >10°C
(at purchase, after
moving or after a long
period of no use.)
Condensation
heater is set for
always ON,
but if the left and
right compartment
are simultaneously
turned off,
condensation
heater is turned
off, too.
The 3-way valve is
opened to both
compartments for 3
minutes; then it is
opened to either
the left or the right
compartment,
depending on the
temperature in the
compartments.
POWER
ON
CONDEN-
SATION
HEATER
ON
3WAY
VALVE
OPEN
3-WAY
VALVE
OPEN
BOTH
3WAY
VALVE
LEFT
OPEN
3-WAY
VALVE
OPEN
LEFT
3-WAY
VALVE
OPEN
BOTH
3-WAY
VALVE
OPEN
LEFT
COMPR-
ESSOR
ON
POWER
ON
CONDEN-
SATION
HEATER
ON
CONDEN-
SATION
HEATER
ON
LEFT
RIPENING
HEATER
ON
RIGHT
RIPENING
HEATER
ON
LEFT
RIPENING
HEATER
OFF
All
LOADS
OFF
RIGHT
RIPENING
HEATER
OFF
COM-
PRESSOR
ON
COM-
PRESSOR
ON
3sec
3min
7min
0.5sec
3sec
3min
10sec
0.5sec
0.5sec
5sec
3sec
3min
10sec
Instantly
Instantly
Instantly
Operation Status
Operation Order
Remarks
Temperature of Left
and Right sensor is
<10°C. (In Power
failure or Service)
Season
Spring
Autumn
Winter
Summer
Operation in response to ambient temperature
In general operation
Storage Temperature
of the left and right
Compartments