![LG GR-B652Y*B Service Manual Download Page 24](http://html.mh-extra.com/html/lg/gr-b652y-b/gr-b652y-b_service-manual_1902647024.webp)
- 24 -
6. TROUBLESHOOTING
6-1 COMPRESSOR AND ELECTRIC COMPONENTS
Power Source.
Check the
resistance of
Motor
Compressor.
Check the
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
Remove the PTC-Starter
from the Compressor and
measure the voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.
No Voltage.
(Rating Voltage
10%)?
Replace OLP.
Check connection
condition.
Reconnect.
Replace
PTC-Starter.
Replace OLP.
O.K.
OLP disconnected?
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
Advise the customer
to use a regular
Trans.
Replace Compressor.
OLP works within 30
sec. in forcible OLP
operation by turning
instant power on and
off.
Components start at
voltage
10% of
rated voltage.
Applied voltage isn't in
the range of Rating
Voltage
10%.
Check the resistance
among M-C, S-C and
M-S in Motor
Compressor.
Check the resistance
of two terminals in
PTC-Starter.
Check if applying
a regular OLP.
Measure minimum
starting voltage after 5
min. for balancing cycle
pressure and cooling the
PTC.
Summary of Contents for GR-B652Y*B
Page 47: ... 47 7 5 2 REPLACEMENT PARTS LIST ...
Page 48: ... 48 ...
Page 49: ... 49 7 5 3 PWB ASS Y DISPLAY AND PARTS LIST ...
Page 50: ... 50 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Page 51: ... 51 7 5 5 V LED DISPLAY PART LIST ...
Page 52: ... 52 7 6 PWB DIAGRAM ...
Page 53: ... 53 ...